LTC3553 Linear Technology Corporation, LTC3553 Datasheet - Page 26

no-image

LTC3553

Manufacturer Part Number
LTC3553
Description
Micropower USB Power Manager
Manufacturer
Linear Technology Corporation
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LTC3553EDE
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC3553EDE#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC3553EDE#TRPBF
Manufacturer:
MICRON
Quantity:
3 000
Part Number:
LTC3553EPD
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC3553EPD#PBF
Manufacturer:
LT
Quantity:
4 235
Part Number:
LTC3553EUD
Manufacturer:
LT
Quantity:
10 000
Part Number:
LTC3553EUD
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC3553EUD#TRPBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC3553EUD-2#PBF
Manufacturer:
LINEAR/凌特
Quantity:
20 000
Part Number:
LTC3553IUD-2
Manufacturer:
LINEAR/凌特
Quantity:
20 000
www.DataSheet.in
LTC3553
OPERATION
PBSTAT to go low. PBSTAT goes high impedance when
ON goes high, except the logic enforces a minimum pulse
width of 50ms on PBSTAT.
In the HR, POFF, PDN1, and PDN2 states, PBSTAT remains
high impedance regardless of the state of ON.
Power-Up Via Pushbutton Press
Figure 8 shows the LTC3553 powering up through ap-
plication of the external pushbutton. For this example
the pushbutton circuitry starts in the POFF or HR state
with a battery connected and both regulators disabled.
Pushbutton application (ON low) for 400ms transitions the
pushbutton circuitry into the PUP state and powers up the
buck followed by the LDO since the SEQ pin is low in this
example. If either BUCK_ON or LDO_ON is low or goes low
after the fi ve second period the corresponding regulator(s)
will be shut down. In the above example LDO_ON is low
at the end of the fi ve second period and therefore the LDO
is disabled at the end of the fi ve second period.
26
STATE
BUCK_ON
LDO_ON
ON (PB)
PBSTAT
BUCK
V
LDO
SEQ
BAT
BUS
Figure 8. Power-Up via Pushbutton Press
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
POFF/HR
400ms
PUP2/PUP1
5s
PON
3553 TD01
The BUCK_ON and LDO_ON inputs can be driven via a
μP/μC or by one of the regulator outputs through a high
impedance (100kΩ typical) to keep the bucks enabled
as described above. PBSTAT does not go low on initial
pushbutton application for power-up, but will go low with
subsequent ON pushbutton applications in the PUP1,
PUP2 or PON states.
Power-Up Via Applying External Power
Figure 9 shows the LTC3553 powering up through ap-
plication of external power (V
pushbutton circuitry starts in the POFF or HR state with
a battery connected and both regulators disabled. 100ms
after V
into the PUP state and powers up the buck followed by the
LDO. The 100ms delay time allows the applied supply to
settle. The regulators will stay powered as long as their
respective BUCK_ON and LDO_ON inputs are driven high
before the fi ve second PUP period is over. If either BUCK_
STATE
BUCK_ON
LDO_ON
ON (PB)
PBSTAT
BUS
Figure 9. Power-Up via Applying External Power
BUCK
V
LDO
SEQ
BAT
BUS
application the pushbutton circuitry transitions
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
POFF/HR
100ms
BUS
PUP2/PUP1
5s
5s
). For this example the
PON
3553 TD02
3553f

Related parts for LTC3553