AD9887A Analog Devices, Inc., AD9887A Datasheet - Page 7

no-image

AD9887A

Manufacturer Part Number
AD9887A
Description
Dual Interface For Flat Panel Displays
Manufacturer
Analog Devices, Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AD9887AKS-140
Manufacturer:
AD
Quantity:
275
Part Number:
AD9887AKS-140
Manufacturer:
TOS
Quantity:
160
Part Number:
AD9887AKS-140
Manufacturer:
AD
Quantity:
586
Part Number:
AD9887AKS-140
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Company:
Part Number:
AD9887AKS-140
Quantity:
120
Part Number:
AD9887AKS-170
Manufacturer:
ADI
Quantity:
421
Part Number:
AD9887AKSZ-100
Manufacturer:
ADI
Quantity:
430
Part Number:
AD9887AKSZ-100
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD9887AKSZ-140
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD9887AKSZ-140
Manufacturer:
ADI/亚德诺
Quantity:
20 000
Part Number:
AD9887AKSZ-170
Manufacturer:
Analog Devices Inc
Quantity:
10 000
Part Number:
AD9887AKSZ-170
Manufacturer:
AD
Quantity:
20 000
ABSOLUTE MAXIMUM RATINGS
Table 3.
Parameter
V
V
Analog Inputs
VREFIN
Digital Inputs
Digital Output Current
Operating Temperature Range
Storage Temperature Range
Maximum Junction Temperature
Maximum Case Temperature
Stresses above those listed under Absolute Maximum Ratings
may cause permanent damage to the device. This is a stress
rating only; functional operation of the device at these or any
other conditions above those indicated in the operational
section of this specification is not implied. Exposure to absolute
maximum rating conditions for extended periods may affect
device reliability.
D
DD
Rating
3.6 V
3.6 V
V
V
5 V to 0.0 V
20 mA
−25°C to +85°C
−65°C to +150°C
150°C
150°C
D
D
to 0.0 V
to 0.0 V
Rev. B | Page 7 of 52
EXPLANATION OF TEST LEVELS
I.
II.
III.
IV.
V.
VI.
ESD CAUTION
100% production tested.
100% production tested at 25°C; sample tested at
specified temperatures.
Sample tested only.
Guaranteed by design and characterization testing.
Parameter is a typical value only.
100% production tested at 25°C; guaranteed by design
and characterization testing.
AD9887A