T315XW01 AUO, T315XW01 Datasheet - Page 21

no-image

T315XW01

Manufacturer Part Number
T315XW01
Description
WXGA Color TFT-LCD Module
Manufacturer
AUO
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
T315XW01-V5
Manufacturer:
AUO
Quantity:
1 000
Part Number:
T315XW01V
Manufacturer:
AUO
Quantity:
1 000
Part Number:
T315XW01V5
Manufacturer:
AUO
Quantity:
1 000
©Copyright AU Optronics, Inc.
January, 2003 All Rights Reserved.
No Reproduction and Redistribution Allowed
8. Packing
9. PRECAUTIONS
9-1 MOUNTING PRECAUTIONS
9-2 OPERATING PRECAUTIONS
Please pay attention to the followings when you use this TFT LCD module.
(1) You must mount a module using holes arranged in four corners or four sides.
(2) You should consider the mounting structure so that uneven force (ex. Twisted stress) is not
applied to module. And the case on which a module is mounted should have sufficient strength so
that external force is not transmitted directly to the module.
(3) Please attach the surface transparent protective plate to the surface in order to protect the
polarizer. Transparent protective plate should have sufficient strength in order to the resist external
force.
(6) Do not touch, push or rub the exposed polarizers with glass, tweezers or anything harder than
(7) When the surface becomes dusty, please wipe gently with absorbent cotton or other soft
(8) Wipe off saliva or water drops as soon as possible. Their long time contact with polarizer
(9) Do not open the case because inside circuits do not have sufficient strength.
(4) You should adopt radiation structure to satisfy the temperature specification.
(5) Acetic acid type and chlorine type materials for the cover case are not desirable because the
(1) The spike noise causes the mis-operation of circuits. It should be lower than following voltage:
(2) Response time depends on the temperature. (In lower temperature, it becomes longer..)
(3) Brightness depends on the temperature. (In lower temperature, it becomes lower.) And in lower
(4) Be careful for condensation at sudden temperature change. Condensation makes damage to
(5) When fixed patterns are displayed for a long time, remnant image is likely to occur.
(6) Module has high frequency circuits. Sufficient suppression to the electromagnetic interference
former generates corrosive gas of attacking the polarizer at high temperature and the latter
causes circuit break by electro-chemical reaction.
HB pencil lead. And please do not rub with dust clothes with chemical treatment. Do not touch
the surface of polarizer for bare hand or greasy cloth. (Some cosmetics are detrimental to the
polarizer.)
materials like chamois soaks with petroleum benzene. Normal-hexane is recommended for
cleaning the adhesives used to attach front/ rear polarizers. Do not use acetone, toluene and
alcohol because they cause chemical damage to the polarizer.
causes deformations and color fading.
V=±200mV(Over and under shoot voltage)
temperature, response time (required time that brightness is stable after turned on) becomes
longer.
polarizer or electrical contacted parts. And after fading condensation, smear or spot will occur.
shall be done by system manufacturers. Grounding and shielding methods may be important to
minimize the interface.
T315XW01 V0 - Specs. Ver0.1
21/24

Related parts for T315XW01