DSPIC30F2012 Microchip Technology Inc., DSPIC30F2012 Datasheet - Page 67

no-image

DSPIC30F2012

Manufacturer Part Number
DSPIC30F2012
Description
Dspic30f2011/2012/3012/3013 High-performance Digital Signal Controllers
Manufacturer
Microchip Technology Inc.
Datasheet

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DSPIC30F2012-20E/ML
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
DSPIC30F2012-20E/SO
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
DSPIC30F2012-20I/ML
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
Part Number:
DSPIC30F2012-20I/SO
Manufacturer:
MICROCHI
Quantity:
20 000
Part Number:
DSPIC30F2012-20I/SO
0
Part Number:
DSPIC30F2012-20I/SP
Manufacturer:
Microchip Technology
Quantity:
135
Part Number:
DSPIC30F2012-20I/SP
Manufacturer:
MICROCHIP/微芯
Quantity:
20 000
8.2
A Reset is not a true exception because the interrupt
controller is not involved in the Reset process. The pro-
cessor initializes its registers in response to a Reset
which forces the PC to zero. The processor then begins
program execution at location 0x000000. A GOTO
instruction is stored in the first program memory loca-
tion immediately followed by the address target for the
GOTO instruction. The processor executes the GOTO to
the specified address and then begins operation at the
specified target (start) address.
8.2.1
In addition to external Reset and Power-on Reset
(POR), there are 6 sources of error conditions which
‘trap’ to the Reset vector.
• Watchdog Time-out:
• Uninitialized W Register Trap:
• Illegal Instruction Trap:
• Brown-out Reset (BOR):
• Trap Lockout:
© 2006 Microchip Technology Inc.
The watchdog has timed out, indicating that the
processor is no longer executing the correct flow
of code.
An attempt to use an uninitialized W register as
an Address Pointer causes a Reset.
Attempted execution of any unused opcodes
results in an illegal instruction trap. Note that a
fetch of an illegal instruction does not result in an
illegal instruction trap if that instruction is flushed
prior to execution due to a flow change.
A momentary dip in the power supply to the
device has been detected which may result in
malfunction.
Occurrence of multiple trap conditions
simultaneously causes a Reset.
Reset Sequence
RESET SOURCES
dsPIC30F2011/2012/3012/3013
8.3
Traps can be considered as non-maskable interrupts
indicating a software or hardware error, which adhere
to a predefined priority as shown in Figure 8-1. They
are intended to provide the user a means to correct
erroneous operation during debug and when operating
within the application.
Note that many of these trap conditions can only be
detected when they occur. Consequently, the question-
able instruction is allowed to complete prior to trap
exception processing. If the user chooses to recover
from the error, the result of the erroneous action that
caused the trap may have to be corrected.
There are 8 fixed priority levels for traps: Level 8
through Level 15, which implies that the IPL3 is always
set during processing of a trap.
If the user is not currently executing a trap, and he sets
the IPL<3:0> bits to a value of ‘0111’ (Level 7), then all
interrupts are disabled, but traps can still be processed.
8.3.1
The following traps are provided with increasing prior-
ity. However, since all traps can be nested, priority has
little effect.
Math Error Trap:
The math error trap executes under the following three
circumstances:
1.
2.
3.
4.
Note:
If an attempt is made to divide by zero, the
divide operation is aborted on a cycle boundary
and the trap is taken.
If enabled, a math error trap is taken when an
arithmetic operation on either accumulator A or
B causes an overflow from bit 31 and the accu-
mulator guard bits are not utilized.
If enabled, a math error trap is taken when an
arithmetic operation on either accumulator A or
B causes a catastrophic overflow from bit 39 and
all saturation is disabled.
If the shift amount specified in a shift instruction
is greater than the maximum allowed shift
amount, a trap occurs.
Traps
If the user does not intend to take correc-
tive action in the event of a trap error
condition, these vectors must be loaded
with the address of a default handler that
simply contains the RESET instruction. If,
on the other hand, one of the vectors
containing an invalid address is called, an
address error trap is generated.
TRAP SOURCES
DS70139E-page 65

Related parts for DSPIC30F2012