Specifications of ST72321M9

Hdflash Endurance
100 cycles, data retention
Clock Sources
crystal/ceramic resonator oscillators, internal RC oscillator and bypass for external clock
Four Power Saving Modes
Halt, Active-Halt,Wait and Slow
Main Clock Controller With
Real time base, Beep and Clock-out capabilities
Two 16-bit Timers With
2 input captures, 2 output compares, external clock input on one timer, PWM and pulse generator modes
8-bit Pwm Auto-reload Timer With
2 input captures, 4 PWM outputs, output compare and time base interrupt, external clock with event detector
ST72321M6 ST72321M9
LD A,sema
edge is detected
CP A,#01
jrne OUT
call call_routine; call the interrupt routine
OUT:LD A,#00
LD sema,A
.call_routine
PUSH A
PUSH X
PUSH CC
.ext1_rt
LD A,#00
LD sema,A
IRET
Case 2: Writing to PxOR or PxDDR with Global In-
terrupts Disabled:
SIM
LD A,PFDR
AND A,#$02
LD X,A
PxOR/PxDDR
LD A,#$90
LD PFDDR,A; Write into PFDDR
LD A,#$ff
LD PFOR,A
LD A,PFDR
AND A,#$02
LD Y,A
PxDDR
LD A,X
cp A,#$02
jrne OUT
TNZ Y
jrne OUT
LD A,#$01
LD sema,A ; set the semaphore to '1' if edge is
detected
RIM
LD A,sema ; check the semaphore status
CP A,#$01
jrne OUT
call call_routine; call the interrupt routine
171/175
; set the interrupt mask
; store the level before writing to
; store the level after writing to PxOR/
; check for falling edge
; reset the interrupt mask
; check the semaphore status if
; entry to call_routine
; entry to interrupt routine
; Write to PFOR
RIM
OUT:
JP while_loop
.call_routine ; entry to call_routine
PUSH A
PUSH X
PUSH CC
.ext1_rt
LD A,#$00
LD sema,A
IRET
14.5
interrupt routine
When an active interrupt request occurs at the
same time as the related flag is being cleared, an
unwanted reset may occur.
Note: clearing the related interrupt mask will not
generate an unwanted reset
Concurrent interrupt context
The symptom does not occur when the interrupts
are handled normally, i.e.
when:
– The interrupt flag is cleared within its own inter-
– The interrupt flag is cleared within any interrupt
– The interrupt flag is cleared in any part of the
If these conditions are not met, the symptom can
be avoided by implementing the following se-
quence:
Perform SIM and RIM operation before and after
resetting an active interrupt request.
Example:
Nested interrupt context:
The symptom does not occur when the interrupts
are handled normally, i.e.
when:
– The interrupt flag is cleared within its own inter-
– The interrupt flag is cleared within any interrupt
rupt routine
routine
code while this interrupt is disabled
rupt routine
routine with higher or identical priority level
SIM
reset interrupt flag
RIM
Clearing
RIM
; entry to interrupt routine
active
interrupts
outside