SAM7S32 Atmel Corporation, SAM7S32 Datasheet - Page 435

no-image

SAM7S32

Manufacturer Part Number
SAM7S32
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM7S32

Flash (kbytes)
32 Kbytes
Pin Count
48
Max. Operating Frequency
55 MHz
Cpu
ARM7TDMI
Hardware Qtouch Acquisition
No
Max I/o Pins
21
Ext Interrupts
21
Usb Speed
No
Usb Interface
No
Spi
1
Twi (i2c)
1
Uart
2
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
8
Self Program Memory
NO
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
3.0 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
3
Output Compare Channels
3
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
No
32.8.13
Name:
Access Type:
• TXRDY: Transmit Ready
0 = Data has been loaded in SSC_THR and is waiting to be loaded in the Transmit Shift Register (TSR).
1 = SSC_THR is empty.
• TXEMPTY: Transmit Empty
0 = Data remains in SSC_THR or is currently transmitted from TSR.
1 = Last data written in SSC_THR has been loaded in TSR and last data loaded in TSR has been transmitted.
• ENDTX: End of Transmission
0 = The register SSC_TCR has not reached 0 since the last write in SSC_TCR or SSC_TNCR.
1 = The register SSC_TCR has reached 0 since the last write in SSC_TCR or SSC_TNCR.
• TXBUFE: Transmit Buffer Empty
0 = SSC_TCR or SSC_TNCR have a value other than 0.
1 = Both SSC_TCR and SSC_TNCR have a value of 0.
• RXRDY: Receive Ready
0 = SSC_RHR is empty.
1 = Data has been received and loaded in SSC_RHR.
• OVRUN: Receive Overrun
0 = No data has been loaded in SSC_RHR while previous data has not been read since the last read of the Status
Register.
1 = Data has been loaded in SSC_RHR while previous data has not yet been read since the last read of the Status
Register.
• ENDRX: End of Reception
0 = Data is written on the Receive Counter Register or Receive Next Counter Register.
1 = End of PDC transfer when Receive Counter Register has arrived at zero.
6175L–ATARM–28-Jul-11
RXBUFF
31
23
15
7
SSC Status Register
ENDRX
30
22
14
SSC_SR
Read-only
6
OVRUN
29
21
13
5
RXRDY
28
20
12
4
TXBUFE
RXSYN
27
19
11
3
TXSYN
ENDTX
26
18
10
2
TXEMPTY
SAM7S Series
RXEN
CP1
25
17
9
1
TXRDY
TXEN
CP0
24
16
8
0
435