SAM3N1B Atmel Corporation, SAM3N1B Datasheet - Page 530

no-image

SAM3N1B

Manufacturer Part Number
SAM3N1B
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of SAM3N1B

Flash (kbytes)
64 Kbytes
Pin Count
64
Max. Operating Frequency
48 MHz
Cpu
Cortex-M3
# Of Touch Channels
17
Hardware Qtouch Acquisition
No
Max I/o Pins
34
Ext Interrupts
34
Quadrature Decoder Channels
2
Usb Speed
No
Usb Interface
No
Spi
3
Twi (i2c)
2
Uart
4
Ssc
1
Graphic Lcd
No
Video Decoder
No
Camera Interface
No
Adc Channels
10
Adc Resolution (bits)
10
Adc Speed (ksps)
384
Resistive Touch Screen
No
Dac Channels
1
Dac Resolution (bits)
10
Temp. Sensor
No
Crypto Engine
No
Sram (kbytes)
8
Self Program Memory
YES
Dram Memory
No
Nand Interface
No
Picopower
No
Temp. Range (deg C)
-40 to 85
I/o Supply Class
1.8/3.3
Operating Voltage (vcc)
1.62 to 3.6
Fpu
No
Mpu / Mmu
no / no
Timers
6
Output Compare Channels
6
Input Capture Channels
3
Pwm Channels
4
32khz Rtc
Yes
Calibrated Rc Oscillator
Yes
Table 30-5.
30.7.1.2
530
530
Baud Rate Calculation Example
Source Clock
12 000 000
12 288 000
14 318 180
14 745 600
18 432 000
24 000 000
24 576 000
25 000 000
32 000 000
32 768 000
33 000 000
40 000 000
50 000 000
3 686 400
4 915 200
5 000 000
7 372 800
8 000 000
MHz
SAM3N
SAM3N
Fractional Baud Rate in Asynchronous Mode
Baud Rate Example (OVER = 0)
Expected Baud
Table 30-5
clock frequencies. This table also shows the actual resulting baud rate and the error.
The baud rate is calculated with the following formula:
The baud rate error is calculated with the following formula. It is not recommended to work with
an error higher than 5%.
The Baud Rate generator previously defined is subject to the following limitation: the output fre-
quency changes by only integer multiples of the reference frequency. An approach to this
problem is to integrate a fractional N clock generator that has a high resolution. The generator
architecture is modified to obtain Baud Rate changes by a fraction of the reference source clock.
This fractional part is programmed with the FP field in the Baud Rate Generator Register
(US_BRGR). If FP is not 0, the fractional part is activated. The resolution is one eighth of the
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
38 400
Rate
Bit/s
BaudRate
Error
shows calculations of CD to obtain a baud rate at 38400 bauds for different source
=
1
Calculation Result
=
ExpectedBaudRate
-------------------------------------------------- -
MCK
ActualBaudRate
12.00
13.02
19.53
20.00
23.30
24.00
30.00
39.06
40.00
40.69
52.08
53.33
53.71
65.10
81.38
6.00
8.00
8.14
CD
×
16
CD
12
13
20
20
23
24
30
39
40
40
52
53
54
65
81
6
8
8
Actual Baud Rate
38 400.00
38 400.00
39 062.50
38 400.00
38 461.54
37 500.00
38 400.00
38 908.10
38 400.00
38 400.00
38 461.54
38 400.00
38 109.76
38 461.54
38 641.51
38 194.44
38 461.54
38 580.25
Bit/s
11011A–ATARM–04-Oct-10
11011A–ATARM–04-Oct-10
0.00%
0.00%
1.70%
0.00%
0.16%
2.40%
0.00%
1.31%
0.00%
0.00%
0.16%
0.00%
0.76%
0.16%
0.63%
0.54%
0.16%
0.47%
Error