AT89C51CC02 Atmel Corporation, AT89C51CC02 Datasheet - Page 86

no-image

AT89C51CC02

Manufacturer Part Number
AT89C51CC02
Description
Manufacturer
Atmel Corporation
Datasheets

Specifications of AT89C51CC02

Flash (kbytes)
16 Kbytes
Max. Operating Frequency
40 MHz
Cpu
8051-12C
Max I/o Pins
20
Uart
1
Can
1
Adc Channels
8
Adc Resolution (bits)
10
Adc Speed (ksps)
62.5
Sram (kbytes)
0.5
Eeprom (bytes)
2048
Self Program Memory
API
Operating Voltage (vcc)
3.0 to 5.5
Timers
4
Isp
UART/CAN
Watchdog
Yes

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
AT89C51CC02CA-RATUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC02CA-SISUM
Manufacturer:
Atmel
Quantity:
972
Part Number:
AT89C51CC02CA-SISUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC02CA-SISUM
Manufacturer:
ATMEL/爱特梅尔
Quantity:
20 000
Part Number:
AT89C51CC02CA-TISUM
Manufacturer:
Atmel
Quantity:
1 492
Part Number:
AT89C51CC02CA-UM
Manufacturer:
AD
Quantity:
10
Part Number:
AT89C51CC02UA-RATUM
Manufacturer:
Atmel
Quantity:
1 845
Part Number:
AT89C51CC02UA-RATUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC02UA-SISUM
Manufacturer:
Atmel
Quantity:
10 000
Part Number:
AT89C51CC02UA-UM
Manufacturer:
NEDI
Quantity:
4
Fault Confinement
86
AT/T89C51CC02
With respect to fault confinement, a unit may be in one of the three following status:
An error active unit takes part in bus communication and can send an active error frame
when the CAN macro detects an error.
An error passive unit cannot send an active error frame. It takes part in bus communica-
tion, but when an error is detected, a passive error frame is sent. Also, after a
transmission, an error passive unit will wait before initiating further transmission.
A bus off unit is not allowed to have any influence on the bus.
For fault confinement, two error counters (TEC and REC) are implemented.
See CAN Specification for details on Fault confinement.
Figure 42. Line Error Mode
Error active
Error passive
Bus off
ERRP = 1
BOFF = 0
REC>127
TEC>127
or
ERRP = 0
BOFF = 0
Passive
Error
REC<127
TEC<127
TEC>255
and
Active
Error
Init.
Bus
Off
128 Occurrences
11 Consecutive
Recessive
bit
of
REC: Receive Error Counter
TEC: Transmit Error Counter
ERRP = 0
BOFF = 1
4126L–CAN–01/08

Related parts for AT89C51CC02