MT90401AB Zarlink, MT90401AB Datasheet - Page 5

no-image

MT90401AB

Manufacturer Part Number
MT90401AB
Description
Framer SDH/SONET 3.3V 80-Pin LQFP EP Tray
Manufacturer
Zarlink
Datasheet

Specifications of MT90401AB

Package
80LQFP EP
Number Of Transceivers
1
Standard Framing Format
SDH|SONET
Maximum Supply Current
150 mA
Minimum Single Supply Voltage
3 V
Maximum Single Supply Voltage
3.6 V

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
MT90401AB
Manufacturer:
ZARLINK
Quantity:
500
Part Number:
MT90401AB1
Manufacturer:
st
Quantity:
421
Pin Description (continued)
Pin #
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
HOLDOVER Holdover (CMOS Output). This output goes high when the device is in holdover mode.
SECOOR
C34/C44
FLOCK
Name
LOCK
RSEL
TCLR
C19o
PCCi
V
V
V
V
C20i
NC
DS
IC
SS5
DD3
SS7
DD4
Digital ground. 0 Volts
Clock 19.44 MHz (CMOS Output). This output is used in OC-N and STM-N applications.
Reference Source Select (Input). A logic low selects the PRI (primary) reference source
as the input reference signal and a logic high selects the SEC (secondary) input. The logic
level at this input is gated in by the rising edge of F8o. For more details see RSEL bit
description in Table 6 - Control Register 1 (Address 00H - Read/Write).
TIE Circuit Clear (Input). A logic low at this input clears the Time Interval Error (TIE)
correction circuit resulting in a realignment of output phase with input phase. The TCLR pin
should be held low for a minimum of 300 ns. When this pin is held low, the time interval error
correction circuit is disabled.
Positive Power Supply. Digital supply.
No Connection.
20 MHz Clock Input (5 V tolerant Input). This pin is the input for the master 20 MHz clock.
Digital ground. 0Volts
Controlled Clock 34.368 MHz / Clock 44.736 MHz (CMOS Output). This output clock is
programmable to be either 34.368 MHz (for E3 applications) or 44.736 MHz (for DS3
applications). The output clock is controlled via control pins in Hardware Mode or control
bits when the device is in Microport Mode.
If the E3DS3/OC3 control pin or control bit is high, the C34/C44 pin will output its nominal
frequency. If the E3DS3/OC3 control pin or bit is low, the C34/C44 pin will output its nominal
frequency divided by 4. (C8.5o/C11o)
Positive Power Supply. Digital supply.
Phase Continuity Control Input (3 V Input). The signal at this pin affects the state
changes between Primary Holdover Mode and Primary Normal Mode and Primary Holdover
Mode and Secondary Normal Mode. The logic level at this input is gated by the rising edge
of F8o. See Figure 12, “Control State Diagram” on page 21 for details.
Lock Indicator (CMOS Output). This output goes high when the PLL is in frequency lock
to the input reference.
Fast Lock Mode (Input). In hardware mode, hold this pin high to lock faster than normal to
the input reference. This pin performs no function if the device is not in hardware mode. In
Fast Lock Mode, the wander generation of the PLL is, of necessity, compromised.
Data Strobe (5 V tolerant Input). This input is the active low data strobe of the Motorola
processor interface.
Internal Connection. Tie low for normal operation.
Secondary Reference Out Of Capture Range (CMOS Output). A logic high at this pin
indicates that the secondary reference is off the PLL center frequency by more than 12
ppm. The measurement is done on a 1 second basis using a signal derived from the
20 MHz clock input on the C20i pin. When the accuracy of the 20 MHz clock is
the effective out of range limits of the SECOOR signal will be
+7.4 ppm to -16.6 ppm.
Zarlink Semiconductor Inc.
MT90401
5
Description
+
16.6 ppm to -7.4 ppm or
Data Sheet
±
4.6 ppm

Related parts for MT90401AB