TXC-04222-AIOG Transwitch Corporation, TXC-04222-AIOG Datasheet - Page 172

no-image

TXC-04222-AIOG

Manufacturer Part Number
TXC-04222-AIOG
Description
Manufacturer
Transwitch Corporation
Datasheet

Specifications of TXC-04222-AIOG

Screening Level
Industrial
Package Type
BGA
Lead Free Status / Rohs Status
Not Compliant
June 2003
TEMx28
TXC-04222
TXC-04222-MB, Ed. 6
Address
082
7-5
Bit
4
3
2
1
0
Proprietary TranSwitch Corporation Information for use Solely by its Customers
LB3UAIS
LB2UAIS
LB1UAIS
LBDPAR
LBDLOC
Symbol
Not used:
B Side Drop Bus Upstream AIS Latched Alarm Indication - STS-3
STS-1 No. 3/AU-3 C: This bit position latches for the B side received
upstream AIS alarm Indication for the STS-3 STS-1 No. 3/AU-3 C for-
mat. This bit is set on either a positive transition, negative transition or
positive and negative alarm transition. This bit is cleared on a read cycle.
B Side Drop Bus Upstream AIS Latched Alarm Indication - STS-3
STS-1 No. 2/AU-3 B: This bit position latches for the B side received
upstream AIS alarm Indication for the STS-3 STS-1 No. 2/AU-3 B for-
mat. This bit is set on either a positive transition, negative transition or
positive and negative alarm transition. This bit is cleared on a read cycle.
B Side Drop Bus Upstream AIS Latched Alarm Indication - STS-3
STS-1 No. 1/AU-3 A/VC4: This bit position latches for the B side
received upstream AIS alarm Indication for the STS-3 STS-1 No. 1/AU-3
A or STM-1 VC-4 format. This bit is set on either a positive transition,
negative transition or positive and negative alarm transition. This bit is
cleared on a read cycle.
B Side Drop Bus Parity Latched Alarm Indication: This bit position
latches for the B side parity error. This bit is set on either a positive tran-
sition, negative transition or positive and negative alarm transition. This
bit is cleared on a read cycle.
B Side Drop Bus Loss Of Clock Latched Alarm Indication: This bit
position latches for the B side loss of clock alarm. This bit is set on either
a positive transition, negative transition or positive and negative alarm
transition. This bit is cleared on a read cycle.