PA28F400BVB60 Intel, PA28F400BVB60 Datasheet - Page 24

no-image

PA28F400BVB60

Manufacturer Part Number
PA28F400BVB60
Description
Manufacturer
Intel
Datasheet

Specifications of PA28F400BVB60

Density
4Mb
Access Time (max)
60ns
Interface Type
Parallel
Boot Type
Bottom
Address Bus
19/18Bit
Operating Supply Voltage (typ)
3.3/5V
Operating Temp Range
0C to 70C
Package Type
SOP
Sync/async
Asynchronous
Operating Temperature Classification
Commercial
Operating Supply Voltage (min)
3/4.5V
Operating Supply Voltage (max)
3.6/5.5V
Word Size
8/16Bit
Number Of Words
512K/256K
Supply Current
65mA
Mounting
Surface Mount
Pin Count
44
Lead Free Status / Rohs Status
Not Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PA28F400BVB60
Manufacturer:
INTEL
Quantity:
45
Part Number:
PA28F400BVB60
Manufacturer:
INTEL
Quantity:
20 000
4-MBIT SmartVoltage BOOT BLOCK FAMILY
24
FULL STATUS CHECK PROCEDURE
Block Erase Successful
Read Status Register
Check if Desired
Data (See Above)
Block Address
Write D0H and
Block Address
Block Erase
Read Status
Write 20H,
Full Status
Complete
Register
SR.4,5 =
SR.3 =
SR.7 =
SR.5 =
Start
0
0
0
1
0
1
1
1
NO
Suspend
Command Sequence
Block Erase Error
Erase
V
Figure 10. Automated Block Erase Flowchart
PP
Range Error
Error
Suspend Erase
YES
Loop
SEE NEW DESIGN RECOMMENDATIONS
Operation
Operation
Repeat for subsequent block erasures.
Full Status Check can be done after each block erase, or after a
Write FFH after the last operation to reset device to read array mode.
SR.3 MUST be cleared, if set during an erase attempt, before further
SR.5 is only cleared by the Clear Status Register Command, in
If error is detected, clear the Status Register before attempting
Standby
Standby
Standby
Standby
sequence of block erasures.
attempts are allowed by the Write State Machine.
cases where multiple blocks are erase before full status is checked.
retry or other error recovery.
Read
Write
Write
Bus
Bus
Erase Setup
Confirm
Command
Command
Erase
Data = 20H
Addr = Within Block to Be Erased
Data = D0H
Addr = Within Block to Be Erased
Status Register Data Toggle CE#
or OE# to Update Status Register
Check SR.7
1 = WSM Ready
0 = WSM Busy
Check SR.3
1 = V
Check SR.4,5
Both 1 = Command Sequence Error
Check SR.5
1 = Block Erase Error
PP
Low Detect
Comments
Comments
0530_10