2308 KEITHLEY, 2308 Datasheet - Page 5

58T8428

2308

Manufacturer Part Number
2308
Description
58T8428
Manufacturer
KEITHLEY
Datasheet

Specifications of 2308

No. Of Outputs
2
Output Voltage
15V
Output Voltage 2
15V
Output Current
5A
Output Current 2
5A
Load Regulation
0.01%
Length
411mm
Width
213mm
Height
89mm
Weight
3.2kg
Power Supply Output Type
Variable
Power Rating
50W

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
2308
Quantity:
5 510
Part Number:
2308
Manufacturer:
MOT
Quantity:
5 510
Part Number:
2308-1HDCG
Manufacturer:
TEMIC
Quantity:
229
Company:
Part Number:
2308-1HDCG8
Quantity:
1 832
Company:
Part Number:
2308-1HDCG8
Quantity:
1 832
Part Number:
2308-1HI
Manufacturer:
IDT
Quantity:
738
Part Number:
2308-2-00-44-00-00-07-0
Manufacturer:
MLL
Quantity:
1 242
Part Number:
2308-2DCG8
Quantity:
1 150
Part Number:
230835
Manufacturer:
MITSUBIS
Quantity:
20 000
Company:
Part Number:
2308B-2DCG8
Quantity:
1 300
Company:
Part Number:
2308B-2DCG8
Quantity:
1 347
2308
OUTPUT #1 (Battery Channel):
DC VOLTAGE OUTPUT (1 Year, 23°C ± 5°C)
OUTPUT VOLTAGE: 0 to +15VDC.
OUTPUT ACCURACY: (0.05% + 3mV).
PROGRAMMING RESOLUTION: 1mV.
READBACK ACCURACY
READBACK RESOLUTION: 1mV.
OUTPUT VOLTAGE SETTLING TIME: 5ms to within stated accuracy.
LOAD REGULATION: 0.01% + 2mV.
LINE REGULATION: 0.5mV.
STABILITY
MEASUREMENT TIME CHOICES: 0.002 to 10PLC
AVERAGE READINGS: 1 to 10.
TRANSIENT RESPONSE:
REMOTE SENSE: 1V max. drop in each lead. Add 2mV to the voltage load regulation specifica-
VARIABLE OUTPUT IMPEDANCE: Range: 0 to 1.00W in 0.01W steps. Value can be changed with
NOTES
1. At PLC (Power Line Cycle) = 1.
2. Following 15 minute warm-up, the change in output over 8 hours under ambient temperature, constant load,
3. PLC = Power Line Cycle. 1PLC = 16.7ms for 60Hz operation, 20ms for 50Hz operation.
4. Recovery to within 20mV of previous level.
5. Remote sense, at terminals 1 and 6, with 4.5m (15 feet) 16 AWG (1.31mm
DC CURRENT (1 Year, 23°C ± 5°C)
CONTINUOUS AVERAGE OUTPUT CURRENT
CHANNEL #2 (CHARGER) OFF:
CHANNEL #2 (CHARGER) ON:
CONTINUOUS AVERAGE SINK CURRENT
CHANNEL #2 (CHARGER) OFF:
CHANNEL #2 (CHARGER) ON:
Transient Recovery Time
Transient Voltage Drop
tion for each 1V change in the negative output lead due to load current change. Remote sense
required. Integrity of connection continually monitored. If compromised, output will turn off
automatically once settable window (±0 to ±8 volts) around normal voltage exceeded.
output on.
I = 50W/(V
I = (50W – power consumed by channel #2)/(V
The power consumed by channel #2 is calculated as:
Channel #2 Sourcing Current: Power consumed = (V
Channel #2 Sinking Current: Power consumed = 5V × (sink current).
0–5V: 3A max.
5–15V: Derate 0.2A per volt above 5V. Compliance setting controls sinking.
Available Current = (50W – Power consumed by channel #2)/5V; 3A max. (0–5V).
Derate 0.2A per volt above 5V.
and line operating conditions.
(0.15A to 1.65A) resistive load only, typical.
1.888.KEITHLEY
w w w.keithley.com
2
: 0.01% + 0.5mV.
set
channel 1 + 6V); 5A max.
1
: ±(0.05% + 3mV).
4
High Bandwidth
<90 mV
<35 µs
1
5
5
(U.S. only)
3
set
, in 0.002PLC steps.
channel 1 + 6V); 5A max.
Low Bandwidth
<180 mV
<50 µs
set
channel 2 + 6V) × (current supplied).
5
5
2
) twisted pair, with 1.5A load change,
Portable Device Battery/Charger Simulator
1
A
DC CURRENT (1 Year, 23°C ± 5°C) (continued)
SOURCE COMPLIANCE ACCURACY: ±(0.16% + 5mA).
PROGRAMMED SOURCE COMPLIANCE RESOLUTION: ±1.25mA.
READBACK ACCURACY:
READBACK RESOLUTION: 5A Range:
LOAD REGULATION: 0.01% + 1mA.
LINE REGULATION: 0.5mA.
STABILITY: 0.01% + 50µA.
MEASUREMENT TIME CHOICES: 0.002 to 10 PLC
AVERAGE READINGS: 1 to 10.
NOTES
1. Peak current can be a max. of 5A provided the average current is within the stated limits and terminals 1 and 6
2. Minimum current in constant current mode is 6mA.
3. PLC = Power Line Cycle. 1PLC = 16.7ms for 60Hz operation, 20ms for 50Hz operation.
PULSE CURRENT MEASUREMENT OPERATION
TRIGGER LEVEL: 5A Range:
TRIGGER DELAY: 0 to 100ms, in 10µs steps.
INTERNAL TRIGGER DELAY: 10µs.
HIGH/LOW/AVERAGE MODE: Measurement Aperture Settings: 33.3µs to 833ms, in 33.3µs
PULSE CURRENT MEASUREMENT ACCURACY
NOTES
1. Based on settled signal: 100µs pulse trigger delay.
2. Also applies to other apertures that are integer multiples of 1PLC.
BURST MODE CURRENT MEASUREMENT
MEASUREMENT APERTURE: 33.3µs to 833ms, in 33.3µs steps.
CONVERSION RATE: 4100/second, typical.
INTERNAL TRIGGER DELAY: 10µs.
NUMBER OF SAMPLES: 1 to 5000.
TRANSFER SAMPLES ACROSS IEEE BUS IN BINARY MODE
NOTES
1. At 33.3µs aperture.
2. Display off, Message Exchange Protocol (MEP) off, auto zero off.
LONG INTEGRATION MODE CURRENT MEASUREMENT
MEASUREMENT TIME, 60Hz (50Hz): 850ms (840ms) to 60 seconds in 1ms steps.
ANALOG OUTPUT
5A/500mA OUTPUT: 1V/A ± 25mA (typical).
50mA/5mA OUTPUT: 1V/10mA ± 0.25mA (typical).
INTERNAL IMPEDANCE: 1000W (nominal).
G R E A T E R
500 µs – <1 PLC
100 µs – 200 µs
200 µs – 500 µs
steps. Average Readings: 1 to 100.
per reading).
are used.
Aperture
<100 µs
>1 PLC
1 PLC
2
M E A S U R E
500mA Range: 0mA to 500mA, in 0.5mA or 500µA steps.
50mA Range: 0mA to 50mA, in 0.05mA or 50µA steps.
5mA Range:
0.3% +
0.3% +
0.3% +
0.3% + 900 µA
0.3% + 900 µA
0.3% + 900 µA
5A Range
5A Range:
500mA Range: ±(0.2% + 100µA).
50 mA Range: ±(0.2% + 5µA).
5mA Range:
500mA Range: 10µA.
50 mA Range:
5mA Range:
2 mA
2 mA
2 mA
0A to 5A, in 5mA steps.
0mA to 5mA, in 0.005mA or 5µA steps.
O F
Accuracy ±(% reading + offset)
500mA Range
0.3% +
0.3% +
0.3% +
0.3% + 900 µA
0.3% + 900 µA
0.3% + 900 µA
1
100µA.
±(0.2% + 200µA).
±(0.2% + 2µA).
C O N F I D E N C E
0.1µA.
1µA.
1
(1 Year, 23°C ± 5°C):
3
, in 0.002PLC steps.
1 mA
1 mA
1 mA
2
50mA Range
0.3% + 700 µA
0.3% + 700 µA
0.3% + 700 µA
0.3% + 500 µA
0.3% + 200 µA
0.3% + 200 µA
2
: 4400 readings/s, typical (4 bytes
0.3% + 200 µA
0.3% + 100 µA
0.3% + 100 µA
0.3% + 90 µA
0.3% + 90 µA
0.3% + 90 µA
5mA Range