PEF 24911
Functional Description
Wait for TN
In “Wait for TN” the U-transceiver waits for a response (tone TN from the NT or tone TL
in case of an analog loop-back) to the transmission of the wake-up signal TL. If no
response is received within T3, the state is left for re-transmission of a wake-up tone TL.
This procedure is repeated until the detection of tone TN or until expiry of timer T1. In
this case the C/I-channel indication EI3 is issued, but no state change is performed.