S3K2U1000-5 SOLA HEVI DUTY, S3K2U1000-5 Datasheet - Page 21

UPS - Uninterruptible Power Supplies 1000VA/750W 230V

S3K2U1000-5

Manufacturer Part Number
S3K2U1000-5
Description
UPS - Uninterruptible Power Supplies 1000VA/750W 230V
Manufacturer
SOLA HEVI DUTY
Datasheet

Specifications of S3K2U1000-5

Power Rating
1000 VA
Output Voltage Rating
230 V
Number Of Outlets
8
Interface Port
USB / SNMP
Runtime (full Load)
5 min
Runtime (half Load)
12 min
Topology
Line Interactive
Tower / Rackmount
Tower / Rackmount
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
1
2
3
4
INTELLISLOT
15. Connect Phone/Fax/DSL/Network/Modem devices to data line connectors.
16. Communication options (see 8.0 - Communications for details):
Option 1 - Serial Communications
Option 2 - Contact Closure Communications
Option 3 - USB Communications
Option 4 – Intellislot
17. REPO Switch—The S3K2U is equipped with a Remote Emergency Power Off (REPO) switch.
connection
RJ11/RJ45
Serial communications provides parametric data, for example, input voltage and battery voltage.
a. Connect MultiLink serial cable included with the UPS to communications port.
b. Install the MultiLink software. The software and installation instructions, as well as the user
Contact Closure communications provides on-battery and low-battery signals for orderly shut-
down.
a. Refer to the MultiLink user manual for instructions on making your own contact closure
b. Install the MultiLink software. The software and installation instructions, as well as the user
a. Connect USB cable provided with the UPS to its USB port and the USB port on your
The UPS contains one communication slot, called “Intellislot™,” to allow the operator to field
install optional communication cards. These optional cards allow the UPS to communicate via
either SNMP Web Card (SNMPWEBCARD), connected directly to the LAN; or Intellislot Relay
Interface card (RELAYCARD-INT) communication card. Once the SNMPWEBCARD is installed,
the Serial communication via the RS232 is disabled. The USB, Intellislot, and Contact Closure
communications operate in parallel.
The user must supply a means of interfacing with the REPO circuit to allow disconnecting the
UPS input feeder breaker to remove all sources of power to the UPS and connected equipment to
comply with national and local wiring codes and regulations.
manual, may be downloaded from www.solaheviduty.com/products/software.
cable.
manual, may be downloaded from www.solaheviduty.com/products/software.
computer. The S3K2U will work automatically with your built-in power management
software on Windows XP and 2000 and Mac OS 10.2 or later (see 8.3 - USB Interface Port
for details).
PUSH TO RESET
BREAKER
INPUT
INPUT
PHONE / FAX / MODEM / NETWORK
IN
PROTECTION
OUT
LOAD 2
LOAD 1
BATTERY
CONNECTOR
1440VA/DC 48V/30A
1000VA/DC 48V/20A
+
-
15
Installation