DS21348G+ Maxim Integrated Products, DS21348G+ Datasheet - Page 41

IC LIU T1/E1/J1 3.3V 49-BGA

DS21348G+

Manufacturer Part Number
DS21348G+
Description
IC LIU T1/E1/J1 3.3V 49-BGA
Manufacturer
Maxim Integrated Products
Type
Line Interface Units (LIUs)r
Datasheet

Specifications of DS21348G+

Number Of Drivers/receivers
1/1
Protocol
T1/E1/J1
Voltage - Supply
3.135 V ~ 3.465 V
Mounting Type
Surface Mount
Package / Case
49-CSBGA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
6. DIAGNOSTICS
6.1 In-Band Loop Code Generation and Detection
The DS21348 can generate and detect a repeating bit pattern that is from one to eight or sixteen bits in
length. To transmit a pattern, the user will load the pattern to be sent into the Transmit Code Definition
(TCD1 and TCD2) registers and select the proper length of the pattern by setting the TC0 and TC1 bits in
the In-Band Code Control (IBCC) register. When generating a 1, 2, 4, 8, or 16 bit pattern both the
transmit code registers (TCD1 and TCD2) must be filled with the proper code. Generation of a 1, 3, 5, or
7-bit pattern only requires TCD1 to be filled. Once this is accomplished, the pattern will be transmitted as
long as the TLCE control bit (CCR3.3) is enabled. As an example, if the user wished to transmit the
standard “loop up” code for Channel Service Units which is a repeating pattern of ...10000100001... then
80h would be loaded into TCD1 and the length would set using TC1 and TC0 in the IBCC register to 5
bits.
The DS21348 can detect two separate repeating patterns to allow for both a “loop up” code and a “loop
down” code to be detected. The user will program the codes to be detected in the Receive Up Code
Definition (RUPCD1 and RUPCD2) registers and the Receive Down Code Definition (RDNCD1 and
RDNCD2) registers and the length of each pattern will be selected via the IBCC register. The DS21348
will detect repeating pattern codes with bit error rates as high as 1x10
integration period of 48ms, hence, after about 48ms of receiving either code, the proper status bit (LUP at
SR.7 and LDN at SR.6) will be set to a one. Normally codes are sent for a period of 5 seconds. It is
recommended that the software poll the DS21348 every 100ms to 1000ms until 5 seconds has elapsed to
insure that the code is continuously present.
IBCC (0AH): IN-BAND CODE CONTROL REGISTER
Table 6-1. Transmit Code Length
(MSB)
SYMBOL
TC1
RDN2
RDN1
RDN0
RUP2
RUP1
RUP0
TC1
TC0
TC0
POSITION
IBCC.7
IBCC.6
IBCC.5
IBCC.4
IBCC.3
IBCC.2
IBCC.1
IBCC.0
RUP2
DESCRIPTION
Transmit Code Length Definition Bit 1. See
Transmit Code Length Definition Bit 0. See
Receive Up Code Length Definition Bit 2. See
Receive Up Code Length Definition Bit 1. See
Receive Up Code Length Definition Bit 0. See
Receive Down Code Length Definition Bit 2. See
Receive Down Code Length Definition Bit 1. See
Receive Down Code Length Definition Bit 0. See
RUP1
41 of 76
RUP0
RDN2
-2
. The code detector has a nominal
RDN1
Table
Table
Table
Table
Table
Table
Table
Table
6-1.
6-1.
6-2.
6-2.
6-2.
6-2.
6-2.
6-2.
RDN0
(LSB)