AD7992BRM-1 Analog Devices Inc, AD7992BRM-1 Datasheet - Page 23

IC ADC 12BIT 2CHAN I2C 10MSOP

AD7992BRM-1

Manufacturer Part Number
AD7992BRM-1
Description
IC ADC 12BIT 2CHAN I2C 10MSOP
Manufacturer
Analog Devices Inc
Datasheet

Specifications of AD7992BRM-1

Number Of Bits
12
Sampling Rate (per Second)
79k
Data Interface
I²C, Serial
Number Of Converters
1
Power Dissipation (max)
2.2mW
Voltage Supply Source
Single Supply
Operating Temperature
-40°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
10-TFSOP (0.118", 3.00mm Width)
For Use With
EVAL-AD7992CB - BOARD EVALUATION FOR AD7992
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
READING DATA FROM THE AD7992
Reading data from the AD7992 is a 1- or 2-byte operation.
Reading back the contents of the alert status register, the config-
uration register, or the cycle timer register is a single-byte read
operation, as shown in Figure 28. This assumes the particular
register address has previously been set up by a single-byte write
operation to the address pointer register (see Figure 25). Once
the register address has been set up, any number of reads can
be performed from that particular register without having to
write to the address pointer register again. If a read from a
different register is required, the relevant register address has
to be written to the address pointer register, and again any
number of reads from this register may then be performed.
SDA
SCL
SDA
SCL
START BY
START BY
MASTER
MASTER
0
1
0
1
1
1
SERIAL BUS ADDRESS BYTE
SERIAL BUS ADDRESS BYTE
0
0
A3
FRAME 1
A3
Figure 29. Reading Two Bytes of Data from the Conversion Result Register
FRAME 1
Figure 28. Reading a Single Byte of Data from a Selected Register
A2
A2
SCL (CONTINUED)
SDA (CONTINUED)
A1
A1
A0
A0
ACK. BY
AD7992
R/W
R/W
Rev. 0 | Page 23 of 28
ACK. BY
AD7992
9
9
ALERT-
FLAG
D7
1
D7
1
1
Reading data from the conversion result register, DATA
registers, DATA
operation, as shown in Figure 29. The same rules apply for a
2-byte read as a 1-byte read.
When reading data back from a register, such as the conversion
result register, if more than two read bytes are supplied, the
same or new data is read from the AD7992 without the need to
re-address the device. This allows the master to continuously
read from a data register without having to re-address the
AD7992.
ZERO
D6
D6
MOST SIGNIFICANT DATA BYTE FROM
MOST SIGNIFICANT DATA BYTE FROM
ZERO CH
D5
SINGLE DATA BYTE FROM AD7992
D5
D4
D4
ID
FRAME 2
FRAME 2
FRAME 2
AD7992
LOW
AD7992
D11
D3
D3
registers, or hysteresis registers is a 2-byte
D2
D10
D2
D1
D1/0
D9
D0
D0/0
D8
NO ACK. BY
NO ACK. BY
MASTER
MASTER
MASTER
ACK. BY
9
9
9
STOP BY
MASTER
STOP BY
MASTER
AD7992
HIGH