5-353293-2 TE Connectivity, 5-353293-2 Datasheet - Page 4

MINI CT MT REC ASSY 2P BLUE

5-353293-2

Manufacturer Part Number
5-353293-2
Description
MINI CT MT REC ASSY 2P BLUE
Manufacturer
TE Connectivity
Datasheets

Specifications of 5-353293-2

Product Type
Connector
Connector Type
Connector Assembly
Termination Method To Wire/cable
IDC
Sealed
No
Ul File Number
E28476
Csa File Number
LR 7189-133
Contact - Rated Current (a)
2
Operating Voltage Reference
AC/DC, AC, DC
Operating Voltage (vac)
50
Operating Voltage (vdc)
50
Wire/cable Size (awg)
26 – 28
Profile Height (y-axis) (mm [in])
6.00 [0.236]
Number Of Positions
2
Number Of Rows
1
Centerline (mm [in])
1.50 [0.059]
Mating Retention
With
Length (x-axis) (mm [in])
4.50 [0.1772]
Width (z-axis) (mm [in])
3.60 [0.141]
Contact Type
Socket
Contact Plating, Mating Area, Material
Pre-Tin
Contact Plating, Mating Area, Thickness (µm [?in])
0.2 [7.87]
Contact Design
Dual Beam
Mating Alignment
With
Housing Color
Blue
Ul Flammability Rating
UL 94V-0
Rohs/elv Compliance
RoHS compliant, ELV compliant
Lead Free Solder Processes
Not relevant for lead free process
Rohs/elv Compliance History
Always was RoHS compliant
Agency/standard
UL, CSA
Operating Temperature (°c [°f])
-30 – +105 [-22 – +221]
Applies To
Wire/Cable
Accepts Wire Insulation Diameter, Range (mm [in])
0.80 – 0.95 [0.030 – 0.037]
Application Use
Wire-to-Board, Wire-to-Board / Wire-to-Wire / Wire-to-Panel, Wire-to-Panel, Wire-to-Wire
Contact Transmits (typical Application)
Signal (Data)
Pick And Place Cover
Without
Packaging Method
Bag, Box
ASHL-0005- ES REV B
3.8 Test Requirements and Procedures Summary:
3.8.1
3.8.2
3.8.3
3.8.4
3.8.5
Para.
Examination of Product
Termination Resistance
(Low Level)
Dielectric withstanding
Voltage
Insulation Resistance
Temperature Rising
Test Items
AMP Shanghai Ltd.
Tyco Electronics
Meets requirements of product
drawing and AMP Specification
114-5223.
10 mΩMax. (Initial)
20 mΩMax. (Final)
No creeping discharge nor
flashover shall occur.
Current leakage : 5 Ma Max.
500 MΩMin. (Initial)
100 MΩMin. (Final)
30 °C Max. under loaded
rating current.
Fig. 2 (To be continued)
Electrical Requirements
Requirements
4 of 17
PAGE
Document No.
108-5525
Visual inspection
No physical damage
Subject mated contacts assembled
in housing to 20 mV Max open
circuit at 10 mA.
Fig.4.
500 VAC for 1 minute.
Test between adjacent circuits of
mated connectors.
MIL STD 202 TEST METHOD
301
Impressed voltage 500 VDC for 1
minute.
Test between adjacent circuits of
mated connectors.
MIL STD 202 TEST METHOD
302 CONDITION A
Contacts series-wired,apply
test current of loaded rating
current to the circuit,and
measure the temperature rising
by probing on soldered areas of
contacts,after the temperature
becomes stabilized Deduct
ambient temperature from the
measured value.
Fig.4
Procedures