IDT1893BFILF IDT, Integrated Device Technology Inc, IDT1893BFILF Datasheet - Page 87

IDT1893BFILF

Manufacturer Part Number
IDT1893BFILF
Description
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDT1893BFILF

Lead Free Status / RoHS Status
Compliant
7.14 Register 19: Extended Control Register 2
ICS1893BF, Rev. E, 8/11/09
The Extended Control Register provides more refined control of the internal ICS1893BF operations.
Note:
1. For an explanation of acronyms used in
2. During any write operation to any bit in this register, the STA must write the default value to all
Table 7-21. Extended Control Register (register [0x13])
† The default is the state of this pin at reset.
19.15 Node Mode
19.14 Hardware/Software
19.13 Remote Fault
19.12 ICS reserved
19.11
19.10 ICS reserved
19.9
19.8
19.7
19.6
19.5
19.4
19.3
19.2
19.1
19.0
Bit
Reserved bits.
ICS1893BF Data Sheet Rev. E - Release
Mode
ICS reserved
AMDIX_EN
MDI_MODE
Twisted Pair Tri-State
Enable, TPTRI
ICS reserved
ICS reserved
ICS reserved
ICS reserved
ICS reserved
ICS reserved
Automatic 100Base-TX
Power Down
Definition
Node mode
No faults detected
Read unspecified
Read unspecified
Read unspecified
See Table 7-22
See Table 7-22
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Hardware mode
Twisted Pair Signals
are not Tri-Stated or
No effect
Do not automatically
power down
When Bit = 0
Copyright © 2009, IDT, Inc.
All rights reserved.
Table
87
7-20, see
Repeater mode
Software mode
Remote fault
detected
Read unspecified
Read unspecified
Read unspecified
See Table 7-22
See Table 7-22
Twisted Pair
Signals are
Tri-Stated
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Read unspecified
Power down
automatically
When Bit = 1
Chapter 1, “Abbreviations and
Chapter 7 Management Register Set
cess
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
RW
Ac-
RO
RO
RO
RO
SF
Acronyms”.
fault
De-
0
1
0
0
0
0
0
0
0
0
0
0
1
0
0
1
August, 2009
Hex
4
2
0
1

Related parts for IDT1893BFILF