SRCS14L Intel (CPU), SRCS14L Datasheet - Page 20

no-image

SRCS14L

Manufacturer Part Number
SRCS14L
Description
Manufacturer
Intel (CPU)
Datasheet

Specifications of SRCS14L

Lead Free Status / RoHS Status
Supplier Unconfirmed
Intel® Integrated RAID Controller SRCS14L
4.1.6
4.1.7
20
Table 9.
Logical Drive Statuses
Logical Drive Statuses
RAID Controller Drive Limitations (Host, Array, Logical, and
Physical)
The following are limitations assuming the following:
Physical drives are limited by the number of ports (four) on the RAID controller. Each physical
drive must be connected to one of the SATA ports. The maximum number of array drives is two. A
RAID array drive requires a minimum of two hard disk drives (or logical drives). Therefore the
maximum RAID array drive limitation for the SRCS14L controller is the physical drive limit
divided by two.
Each RAID array drive (up to two) can contain up to a maximum of two host drives. This means
that the SRCS14L controller has a maximum limitation of four host drives. Also, each array drive
must have at least one host drive. A host drive can only be associated with (or reside on) a single
array drive.
RW = Read Write
RO = Read Only
Drive Status
Four SATA ports
Cabling that meets SATA specifications 1.0
Table 10. RAID Controller Drive Maximum Limitations (SRCS14L)
Missing
Ready
Fault
Physical Disk Drives
RAID Array Drives
RAID Host Drives
Attribute
Drive Type
RW
RW
-
The drive is operational and functioning normal.
The drive is missing or no longer detected by the RAID controller.
The drive is no longer operating within expected parameters.
The drive attribute indicates the level of host OS access to the drive.
Controller
Per RAID
4
2
4
Per Array Drive
Description
Technical Product Specification
N/A
4
2
Per Host Drive
N/A
4
1