SRCS14L Intel (CPU), SRCS14L Datasheet - Page 19

no-image

SRCS14L

Manufacturer Part Number
SRCS14L
Description
Manufacturer
Intel (CPU)
Datasheet

Specifications of SRCS14L

Lead Free Status / RoHS Status
Supplier Unconfirmed
4.1.5
Technical Product Specification
Table 8. Host Array Drive Statuses
RAID Host/Array Drive Statuses
Table 8
RW = Read Write
RO = Read Only
Drive Status
Rebuild
Expand
Ready
Patch
Build
Error
Idle
Fail
lists the available states of RAID Host and Array Drives.
Attribute
RW
RW
RW
RW
RW
RW
RW
RO
RAID 1 / 4 / 5 / 10
RAID 1 / 4 / 5 / 10
RAID 1 / 4 / 5 / 10
RAID 1 / 4 / 5 / 10
RAID 4 / 5 / 10
RAID 4 / 5 / 10
Drive Type
RAID 4 / 5
RAID 4 / 5
Intel® Integrated RAID Controller SRCS14L
The drive attribute indicates the level of host OS
access to the drive
Redundant
adding new
Yes when
using free
No when
drives.
space.
Yes
Yes
No
No
No
No
No
Newly defined array prior to build
process starting.
The initial process of configuring
redundancy information upon creation
of drive.
The array drive is fully operational, its
normal state.
Array drive assumes this status after
the automatic activation of a Hot Fix or
after manual replacement (hot plug).
This status indicates that the RAID
level and or capacity are (is) being
migrated.
The Expand status combines with the
Ready and Fail statuses as shown
below:
This status indicates that a logical
drive has failed.
This status indicates that more that
one logical drive has failed. In this
event, the array is set to read only.
This status indicates that the array
drive has gone through a significant
procedure or has been patched from
the error status to fail status.
The Patch status combines with other
statuses as shown below:
Ready/Expand
Fail/Expand
Ready/Patch
Fail/Patch
Error/Patch
Idle/Patch
Rebuild/Patch
Description
19