PCF8583P NXP Semiconductors, PCF8583P Datasheet - Page 11

PCF8583P

Manufacturer Part Number
PCF8583P
Description
Manufacturer
NXP Semiconductors
Datasheet

Specifications of PCF8583P

Bus Type
Serial (2-Wire, I2C)
Operating Supply Voltage (typ)
3.3/5V
Package Type
PDIP
Operating Supply Voltage (max)
6V
Operating Supply Voltage (min)
2.5V
Operating Temperature Classification
Industrial
Operating Temperature (max)
85C
Operating Temperature (min)
-40C
Pin Count
8
Mounting
Through Hole
Date Format
DW:DM:M:Y
Time Format
HH:MM:SS:hh
Lead Free Status / RoHS Status
Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
PCF8583P
Manufacturer:
SAMSUNG
Quantity:
1 001
Part Number:
PCF8583P
Manufacturer:
NXPLIPS
Quantity:
5 510
Part Number:
PCF8583P
Manufacturer:
NXP
Quantity:
100
Part Number:
PCF8583P
Manufacturer:
PHI
Quantity:
1 000
Part Number:
PCF8583P
Manufacturer:
PHILIPS
Quantity:
10 000
Part Number:
PCF8583P
Manufacturer:
PHILIPS/飞利浦
Quantity:
20 000
Part Number:
PCF8583P/F5
Manufacturer:
TI
Quantity:
90
Part Number:
PCF8583P/F5,112
Manufacturer:
LTC
Quantity:
147
Part Number:
PCF8583P/F5,112
Manufacturer:
NXP
Quantity:
1 688
Part Number:
PCF8583PN
Manufacturer:
PHI
Quantity:
20 000
NXP Semiconductors
PCF8583
Product data sheet
7.7 Timer
The timer (location 07h) is enabled by setting the control and status register to
XX0X X1XX. The timer counts up from 0 (or a programmed value) to 99. On overflow, the
timer resets to 0. The timer flag (LSB of control and status register) is set on overflow of
the timer. This flag must be reset by software. The inverted value of this flag can be
transferred to the external interrupt by setting bit 3 of the alarm control register.
Additionally, a timer alarm can be programmed by setting the timer alarm enable (bit 6 of
the alarm control register). When the value of the timer equals a pre-programmed value in
the alarm timer register (location 0Fh), the alarm flag is set (bit 1 of the control and status
register). The inverted value of the alarm flag can be transferred to the external interrupt
by enabling the alarm interrupt (bit 6 of the alarm control register).
Resolution of the timer is programmed via the 3 LSBs of the alarm control register (see
Figure
Fig 11. Selection of alarm weekdays
12).
MSB
013aaa375
7
6
All information provided in this document is subject to legal disclaimers.
5
Rev. 06 — 6 October 2010
4
3
2
1
LSB
0
Clock and calendar with 240 x 8-bit RAM
memory location 0Eh (alarm_weekday/month)
weekday 0 enabled when set
weekday 1 enabled when set
weekday 2 enabled when set
weekday 3 enabled when set
weekday 4 enabled when set
weekday 5 enabled when set
weekday 6 enabled when set
not used
PCF8583
© NXP B.V. 2010. All rights reserved.
11 of 37

Related parts for PCF8583P