DUO-TOUCH
Two-Hand Control Module AT-..M-11KM provides seven indicator LEDs
Power (Green)
Fault (Red)
Input #1 (Green)
Input #2 (Green)
Safety Stop Input (Green)
Mute (Green)
Output (Green)
and the Module will not reset, do not tap,
strike, or otherwise attempt to correct the
fault by a physical impact to the housing.
An internal relay may have failed in such a
manner that its replacement is required.
If the Module is not immediately replaced
or repaired, multiple simultaneous failures
may accumulate such that the safety
function can not be guaranteed.
!
Banner Engineering Corp.
www.bannerengineering.com • Tel: 763.544.3164
CAUTION ...
Module After Failure
If an internal fault has occurred
®
SG –
Abuse of
ON – Power is connected to terminals A1-A2.
OFF – No power or low power to terminals A1-A2, or internal power supply failure.
Flashing (only; no other LEDs are ON) – DIP Switch Fault. See page 6.
ON – External fault or configuration fault. The corresponding function LED (see below) will flash to indicate the
OFF – Normal operation.
Flashing (only; no other LEDs are ON other than “power”) – Internal Fault. See above for repair.
ON – touch button (Input #1) is activated.
OFF – touch button is not activated.
Flashing – See Troubleshooting Table for probable cause.
ON – touch button (Input #2) is activated.
OFF – touch button is not activated.
Flashing – See Troubleshooting Table for probable cause.
ON – SSI inputs are closed (X3/X4 and X5/X6).
OFF – SSI inputs are open.
Flashing – See Troubleshooting Table for probable cause.
ON – M1/M2 are closed and mute cycle is activated.
OFF – M1/M2 are not closed (mute cycle not activated).
Flashing – Mute cycle is prevented because of M1/M2 simultaneity error, Mute Lamp error,
ON – Both internal relays K1 and K2 are energized. (Safety outputs 13-14 and 23-24 are closed. Auxiliary output
OFF – Both internal relays K1 and K2 are de-energized. (Safety outputs 13-14 and 23-24 are open. Auxiliary
Flashing – Y1/Y2 Feedback Input open.
Minneapolis, MN U.S.A.
area where the fault has been detected. See below or the Troubleshooting Table for probable cause.
31-32 is open.)
output 31-32 is closed.)
Models AT-GM-11KM and AT-HM-11KM Two-Hand Control Modules
Mute Enable not closed before M1/M2 active, power-up with M1/M2 closed,
Backdoor timer expired with M1/M2 closed.
NOTE: Do not attempt any repairs to the DUO-TOUCH SG Two-Hand Control Module.
If it ever becomes necessary to return a DUO-TOUCH SG Safety Module to the factory,
please do the following:
1) Contact the Banner Factory Application Engineering Group at the address or at the
2) Pack the component carefully. Damage which occurs in return shipping is not
numbers listed at the bottom of the back page. They will attempt to troubleshoot
the system from your description of the problem. If they conclude that a
component is defective, they will issue an RMA (Return Merchandise
Authorization) number for your paperwork, and give you the proper shipping
address.
covered by warranty.
It contains no field-replaceable components. Return it to the factory for
warranty repair or replacement.