D4NS-3CF Omron, D4NS-3CF Datasheet - Page 6

DoorSwitch/NPT/2NC1NO

D4NS-3CF

Manufacturer Part Number
D4NS-3CF
Description
DoorSwitch/NPT/2NC1NO
Manufacturer
Omron
Series
D4NSr
Type
Safety Door Key Switchr
Datasheets

Specifications of D4NS-3CF

Circuit
3PST (2-NC, 1-NO)
Switch Function
On-Off, Off-On
Contact Rating @ Voltage
3A @ 250VAC
Actuator Type
Panel Disconnect
Mounting Type
Chassis Mount
Termination Style
Screw Terminal
Operating Force
1500gf
Contact Form
2 NC / 1 NO
Contact Rating
10 Amps at 120 VoltsAC, 240 VoltsAC
Actuator
Key
Key Type
Key
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
D4NS3CF
Z2733
Dimensions
Note: All units are in millimeters unless otherwise indicated.
■ Switches
1-Conduit Models
2-Conduit Models
1-Conduit Connector Models
Note: 1. Unless otherwise specified, a tolerance of 0.4 mm applies to all dimensions.
D4NS-9@F
D4NS-5@F
D4NS-6@F
D4NS-7@F
D4NS-8@F
D4NS-1@F
D4NS-2@F
D4NS-3@F
D4NS-4@F
2.
There are fluctuations in the contact ON/OFF timing for Switches with multiple poles (2NC, 2NC/1NO, or 3NC). Confirm performance before
application.
Black
Red
Red
Black
Red
Black
41
47
39
33.5
0.2
(14)
41 33.5
55
41 33.5
55
5.4
47
47
0.2
0.2
56 max.
20
22
22
20
22
22
30.2
15.3
42
40
20
22
42
30.2
15.3
31
30.2
15.3
31
0.1
0.1
0.2
0.1
0.1
0.2
Head cap
0.1
0.1
0.1
0.1
0.2
Head cap
Head cap
2.15 0.05R
mounting holes
2.15±0.05R
mounting holes
M12
7.5
7.5
4.4
2.5
4.4
4.4
2.5
2.15 0.05R
mounting holes
2.5
25 dia.
3
7.5
1
9
0.2
30.6
31.5
31.5
30.6
30
30
21.5
21.5
15.5
15.5
14.2
14.2
31.5
30.6
30
21.5
Two, 4
depth: 5
15.5
Two, 4
depth: 5
14.2
Two, 4
depth: 5
+0.15
+0.15
0
0
20.5
Cap
dia. holes
dia. holes
+0.15
0
dia. holes
Safety-door Switch
Operating
characteristics
Key insertion force
Key extraction force
Pretravel (PT)
Total travel (TT)
Direct opening force
Direct opening stroke
*
*
Operating
characteristics
Key insertion force
Key extraction force
Pretravel (PT)
Total travel (TT)
Direct opening force
Direct opening stroke
*
for safe use.
Always maintain the above operating characteristics
Operating
characteristics
Key insertion force
Key extraction force
Pretravel (PT)
Total travel (TT)
Direct opening force
Direct opening stroke
for safe use.
Always maintain the above operating characteristics
for safe use.
Always maintain the above operating characteristics
D4NS
*
*
*
*
*
*
D4NS-1@F
D4NS-2@F
D4NS-3@F
D4NS-4@F
15 N max.
30 N max.
60 N min.
10 mm min.
D4NS-9@F
15 N max.
30 N max.
D4NS-5@F
D4NS-6@F
D4NS-7@F
D4NS-8@F
60 N min.
10 mm min.
15 N max.
30 N max.
60 N min.
10 mm min.
(28 mm)
6 3 mm
(28 mm)
6 3 mm
(28 mm)
6 3 mm
A-9

Related parts for D4NS-3CF