D4NS-9AF Omron, D4NS-9AF Datasheet

no-image

D4NS-9AF

Manufacturer Part Number
D4NS-9AF
Description
Safety Door Switch
Manufacturer
Omron
Series
D4NSr
Datasheet

Specifications of D4NS-9AF

Lead Free Status / Rohs Status
 Details
Multi-contact, Labor-saving,
Environment-friendly, Next-generation
Safety-door Switch
Model Number Structure
Model Number Legend
Switch
1. Conduit/Connector size
2. Built-in Switch
3. Head Mounting Direction
Note: An order for the head part or the switch part alone cannot be
D4NS-@@@
• Lineup includes three contact models with 2NC/1NO and
• M12-connector models are available, saving on labor and
• Standardized gold-clad contacts provide high contact
• Variety of metallic heads available.
Safety-door Switch
D4NS
3NC contact forms and MBB models in addition to the
previous contact forms 1NC/1NO, and 2NC.
simplifying replacement.
reliability.
Applicable to both standard loads and microloads.
1:Pg13.5 (1-conduit)
2:G1/2 (1-conduit)
3:1/2-14NPT (1-conduit)
4:M20 (1-conduit)
5:Pg13.5 (2-conduit)
6:G1/2 (2-conduit)
7:1/2-14NPT compatible (2-conduit model with M20 conduit size
8:M20 (2-conduit)
9:M12 connector (1-conduit)
A:1NC/1NO (slow-action)
B:2NC (slow-action)
C:2NC/1NO (slow-action)
D:3NC (slow-action)
E:1NC/1NO (MBB contact)
F:2NC/1NO (MBB contact)
F:Four mounting directions possible (Front-side mounting at
D:Four mounting directions possible (Front-side mounting at
includes an M20-to-1/2-14NPT conversion adapter)
shipping)/plastic
shipping)/metal
accepted. (The Operation Key is sold separately.)
Be sure to read the “Safety Precautions” on page 10 and
the “Precautions for All Safety Door Switches”.
1 2 3
Operation Key
1. Operation Key Type
D4DS-K@
1:Horizontal mounting
2:Vertical mounting
3:Adjustable mounting (Horizontal)
5:Adjustable mounting (Horizontal/Vertical)
1
CSM_D4NS_DS_E_5_1
1

Related parts for D4NS-9AF

D4NS-9AF Summary of contents

Page 1

... D:Four mounting directions possible (Front-side mounting at shipping)/metal Note: An order for the head part or the switch part alone cannot be accepted. (The Operation Key is sold separately.) Operation Key D4DS- Operation Key Type 1:Horizontal mounting 2:Vertical mounting 3:Adjustable mounting (Horizontal) 5:Adjustable mounting (Horizontal/Vertical) CSM_D4NS_DS_E_5_1 1 ...

Page 2

... D4NS-3CF D4NS-4CF D4NS-1DF * D4NS-2DF * D4NS-3DF D4NS-4DF D4NS-1EF D4NS-2EF D4NS-3EF D4NS-4EF D4NS-1FF D4NS-2FF D4NS-3FF D4NS-4FF D4NS-5AF D4NS-6AF D4NS-7AF D4NS-8AF D4NS-5BF D4NS-6BF D4NS-7BF D4NS-8BF D4NS-5CF D4NS-6CF D4NS-7CF D4NS-8CF D4NS-5DF D4NS-6DF D4NS-7DF D4NS-8DF D4NS-5EF D4NS-6EF D4NS-7EF D4NS-8EF D4NS-5FF D4NS-6FF D4NS-7FF D4NS-8FF D4NS-9AF D4NS-9BF D4NS-9EF 2 ...

Page 3

... Consult your OMRON representative A300 for details. E76675 Rated Carry current voltage 2003010305077330 120 VAC 2005-197 240 VAC Q300 Rated Carry current voltage 125 VDC 250 VDC D4NS Utilization AC-15 DC-13 category ) 240 V 250 V e Current (A) Volt-amperes (VA) Make Break Make ...

Page 4

... Although the switch box is protected from dust or water penetration, do not use the D4NS in places where foreign material may enter through the key hole on the head, otherwise Switch damage or malfunctioning may occur. *2. The durability is for an ambient temperature 35°C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative ...

Page 5

... Structure and Nomenclature Structure D4NS-@A@, D4NS-@B@, D4NS-@E@ Operation key hole Terminal 11 Terminal 31 (33) Contact Form Diagrams Show State with Key Inserted. Model Contact D4NS-@A@ 1NC/1NO D4NS-@B@ 2NC D4NS-@C@ 2NC/1NO D4NS-@D@ 3NC 1NC/1NO MBB * D4NS-@E@ 2NC/1NO MBB * D4NS-@F@ * MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally open contact (NO) closes ...

Page 6

... D4NS (Unit: mm) Model D4NS-1@F D4NS-2@F Operating D4NS-3@F characteristics D4NS-4@F Key insertion force 15 N max. Key extraction force 30 N max. Pretravel (PT) 6±3 mm Total travel (TT) (28 mm) Direct opening force * 60 N min. Direct opening stroke * 10 mm min. * Always maintain the above operating characteristics for safe use ...

Page 7

... Four, 2.15R D4DS-K2 10 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions D4DS- Black 2 6.3 D4DS-K5 20 Four, 2.15R Black D4NS Angle adjustment screw 9 dia. 8 dia. 4.5 dia 20° Mounting Holes 24.6 (Enlargement) Angle 22.5 17 adjustment screws 15 15° 18° 6.5 (7) ...

Page 8

... R ≥ 200 (15) Permissible difference in center lines between the Operation Key and key hole is ±1. Vertical key insertion radius R ≥ 200 (33.5) D4NS-1@F + D4DS-K2 (with Top-inserted Operation Key) Horizontal key insertion radius R ≥ 200 Vertical key insertion radius R ≥ 200 (33.5) D4NS Horizontal key insertion radius R ≥ ...

Page 9

... Operation Key and key hole is ±1. Vertical key insertion radius R ≥ 200 (33.5) Permissible difference in center lines between the Operation Key and key hole is ±1. D4NS-1@F + D4DS-K5 (with Top-inserted Operation Key) (43 ) ±0.1 (41 ±0.1 ) Permissible difference in center lines between the Operation Key and key hole is ± ...

Page 10

... Operation Key may exceed the set zone because of, for example, the door's own weight, machine vibration, or the door cushion rubber. Secure the door with a stopper so that the Operation Key remains within the set zone. Set zone (0 mm) Operation Key D4NS Two ±0.1 Two ±0.1 ...

Page 11

... Switch, and used the above connector. D4NS-@CF (2NC/1NO) D4NS-@FF (2NC/1NO (MBB D4NS-@AF (1NC/1NO) D4NS-@EF (1NC/1NO (MBB D4NS-9AF (1NC/1NO) D4NS-9BF (2NC) D4NS-9EF (1NC/1NO (MBB (11) 2 (12) 1 (11) 2 (12) 3 (31) 4 (32) 3 (33) 4 (34) Pin No. (Terminal No.) Applicable cable Manufacture Model diameter ST-PF1/2 LAPP 6.0 to 12.0 mm 5380-1002 S-13.5 LAPP 6 ...

Page 12

... D4DS-65FS D4DS-1AFS D4DS-2AFS D4DS-3AFS D4DS-5AFS D4DS-6AFS Operation Key • D4DS-K1 • D4DS-K2 • D4DS-K3 • D4DS-K5 All of the above Operation Keys can be used with the D4NS. Recommended Substitute Product (1-Conduit D4NS) 30.5 15.5 41 33.5 21.5 47 ± 0.2 +0.15 55 Two, 4 dia. hol 31 ...

Page 13

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...