BK2534 B&K Precision, BK2534 Datasheet - Page 35

OSCOPE 60MHZ DIGITAL STORAGE

BK2534

Manufacturer Part Number
BK2534
Description
OSCOPE 60MHZ DIGITAL STORAGE
Manufacturer
B&K Precision
Type
Bench, Digitalr
Datasheets

Specifications of BK2534

Includes
Probes, Software, USB Cable
Bandwidth
60MHz
Channels
Dual
Display Type
LCD - Color
Features
Software Controllable, USB Port, Waveform Capture
Probe Type
PR-37A x1/x10/Ref Probes (2)
Sampling Rate (per Second)
400MSa/s
Input Impedance
1M - 19pF
Rise Time (typ)
5.83nS
Voltage - Input, Max
400Vpeak
Voltage - Supply
100 ~ 240VAC
Lead Free Status / RoHS Status
Not applicable / Not applicable
Press the Mode softkey to select the Average mode.
  Press the Mode softkey to select the Peak Detect mode.
 
Sampling
Averages
Sampling
Softkey
Softkey
Mode
Record
Mode
Equivalent Equivalent sampling.
Real Time
Options
Average
Equivalent Equivalent sampling.
Real Time
Normal
Detect
Options
Average
Normal
Peak
Detect
Peak
----
Description
Normal acquisition.
Averages
waveforms.
Peak
acquisition.
Real time sampling.
Normal acquisition.
Averages
waveforms.
Peak
acquisition.
Set
number to 2, 4, 8, 16,
32, 64, 128, or 256.
Real time sampling.
Select Record menu.
Basic Operation
Description
the
average
detect
detect
the
the
 
69
70
Basic Operation
Connect a sine wave signal to the CH1 channel, press
knob to set the number of averages to 16. The following two
figures show the difference between Normal acquisition and
Average acquisition.
 
ACQUIRE → Mode to select Average mode. Turn the Entry
Random noise on the displayed waveform
Record
 
----
Select Record menu.