FLUKE-87-5-EX Fluke Electronics, FLUKE-87-5-EX Datasheet - Page 36

no-image

FLUKE-87-5-EX

Manufacturer Part Number
FLUKE-87-5-EX
Description
MULTIMETER INDUSTRIAL TRU RMS
Manufacturer
Fluke Electronics
Series
8xr
Type
Digital (DMM)r
Datasheets

Specifications of FLUKE-87-5-EX

Includes
Battery, Clips, Temperature Probe, Test Leads
Style
Handheld
Display Digits
4.5
Display Type
LCD, Bar Graph
Display Count
20000
Function
Voltage, Current, Resistance, Capacitance, Temperature, Frequency
Functions, Extra
Continuity, Diode Test
Features
Auto Off, Backlight, Clips, Hold, Min/Max/Ave
Ranging
Auto/Manual
Response
True RMS
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
2547226
Users Manual
3.
4.
5.
6.
7.
28
If you are using the A terminal, set the rotary switch to
mA/A. If you are using the mA/ A terminal, set the
rotary switch to A for currents below 6000 A
(6 mA), or mA/A for currents above 6000 A.
To measure dc current, press
Break the circuit path to be tested. Touch the black
probe to the more negative side of the break; touch
the red probe to the more positive side of the break.
Reversing the leads will produce a negative reading,
but will not damage the Meter.
Turn on power to the circuit; then read the display. Be
sure to note the unit given at the right side of the
display ( A, mA, or A).
Turn off power to the circuit and discharge all high-
voltage capacitors. Remove the Meter and restore the
circuit to normal operation.
A.
The following are some tips for measuring current:
If the current reading is 0 and you are sure the Meter
is set up correctly, test the Meter's fuses as described
under "Testing the Fuses".
A current Meter drops a small voltage across itself,
which might affect circuit operation. You can calculate
this burden voltage using the values listed in the
Current Function specifications table.