Specifications of CY7C68320C-100AXA

Controller Type
USB 2.0 Controller
Interface
I²C
Voltage - Supply
3 V ~ 3.6 V
Current - Supply
50mA
Operating Temperature
-40°C ~ 85°C
Mounting Type
Surface Mount
Package / Case
100-LQFP
Package
100TQFP
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
428-3035

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
CY7C68320C-100AXA
Manufacturer:
Cypress Semiconductor Corp
Quantity:
135
Part Number:
CY7C68320C-100AXA
Manufacturer:
Cypress
Quantity:
168
Part Number:
CY7C68320C-100AXA
Manufacturer:
Cypress Semiconductor Corp
Quantity:
10 000
Part Number:
CY7C68320C-100AXA
Manufacturer:
CYPRESS/赛普拉斯
Quantity:
20 000
Part Number:
CY7C68320C-100AXAT
Manufacturer:
Cypress Semiconductor Corp
Quantity:
10 000
Table 6. ATACB Field Descriptions (continued)
Document Number: 001-05809 Rev. *H
13–15
5–12
Byte
3
4
bmATACBRegisterSelect
bATACBTransferBlockCount
bATACBTaskFileWriteData
Reserved
Field Name
This field controls which of the TaskFile register read or write accesses occur.
TaskFile read data is always 8 bytes in length, and unselected register data
are returned as 0x00. Register accesses occur in sequential order as outlined
here (0 to 7):
Bit 0 (0x3F6) Device Control/Alternate Status
Bit 1 (0x1F1) Features/Error
Bit 2 (0x1F2) Sector Count
Bit 3 (0x1F3) Sector Number
Bit 4 (0x1F4) Cylinder Low
Bit 5 (0x1F5) Cylinder High
Bit 6 (0x1F6) Device/Head
Bit 7 (0x1F7) Command/Status
This value indicates the maximum requested block size be in 512-byte
increments. This value must be set to the last value used for the ’Sectors per
block’ in the SET_MULTIPLE_MODE command. Legal values are 0, 1, 2, 4, 8,
16, 32, 64, and 128 where ‘0’ indicates 256 sectors per block. A command
failed status is returned if an illegal value is used in the ATACB.
These bytes contain ATA register data used with ATA command or PIO write
operations. Only registers selected in bmATACBRegisterSelect are required to
hold valid data when accessed. The registers are as follows.
ATACB Address Offset 0x05 (0x3F6) – Device Control
ATACB Address Offset 0x06 (0x1F1) – Features
ATACB Address Offset 0x07 (0x1F2) – Sector Count
ATACB Address Offset 0x08 (0x1F3) – Sector Number
ATACB Address Offset 0x09 (0x1F4) – Cylinder Low
ATACB Address Offset 0x0A (0x1F5) – Cylinder High
ATACB Address Offset 0x0B (0x1F6) – Device
ATACB Address Offset 0x0C (0x1F7) – Command
These bytes must be set to 0x00 for ATACB commands.
Field Description
CY7C68300C, CY7C68301C
CY7C68320C, CY7C68321C
Page 18 of 44