71M6521DEIM-DB Maxim Integrated Products, 71M6521DEIM-DB Datasheet - Page 79

no-image

71M6521DEIM-DB

Manufacturer Part Number
71M6521DEIM-DB
Description
Power Management Modules & Development Tools 71M6521DE DEMO BOARD M6521DE DEMO BOARD
Manufacturer
Maxim Integrated Products
Datasheet

Specifications of 71M6521DEIM-DB

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
71M652X Software User’s Guide
A sag is defined as an undervoltage condition that persists for more than one period. A shorter undervoltage condition
is called a dip (see Figure Figure 5-22). The occurrence of sags can announce an impending loss of power. Since
accumulated energy values etc. in the meter will have to be saved to non-volatile memory in the case of loss of power,
a sag can be used to initiate data saving operations. Some applications may instead save or count the sag event for
the purpose of recording power quality data.
Sag detection is performed by the CE, based on the CE DRAM registers SAG_THR and SAG_CNT. SAG_THR defines
the threshold which the input voltage has to be continuously below, and SAG_CNT defines the number of samples
required to trigger the sag bit (see Figure 5-23).
When the CE detects a sag that meets the sag conditions specified in SAG_THR and SAG_CNT on one of the input
voltage channels, it will reflect this in the corresponding bit (SAG for single-phase, or SAG_A, SAG_B, SAG_C for poly-
phase) of the CE STATUS Word. See the CE Interface section in the 652X Data Sheet for details.
It is up to the MPU firmware to decide what is to be done in case a sag is detected. The Demo Code does not have any
provisions for actions due to sags detected by the CE.
The temperature output of the on-chip temperature sensor (TEMP_RAW) is provided by the CE in CE DRAM location
0x7B. The relative chip temperature deltaT (MPU location 0x20) is derived by subtracting the raw temperature from the
nominal temperature (TEMP_NOM) and multiplying it with a constant factor. Thus, once the raw temperature obtained
at a known environmental temperature is stored in TEMP_NOM, deltaT will always reflect the deviation from nominal
temperature. The scaling is in tenths of Centigrades, i.e. a reading of 75 means that the measured temperature is
7.5°C higher than the reference temperature.
Revision 1.7
5.14 FIRMWARE APPLICATION INFORMATION
5.14.1
5.14.2
Sag Detection
Temperature Measurement
16.67ms
16.67ms
16.67ms
© Copyright 2005-2007 TERIDIAN Semiconductor Corporation
SAG_THR
SAG_THR
Figure 5-22: Sag and Dip Conditions
Figure 5-23: Sag Event
TERIDIAN Proprietary
sag
dip
84 samples
84 samples
SAG_CNT
SAG_CNT
79 of 138

Related parts for 71M6521DEIM-DB