E3G-L77 Omron, E3G-L77 Datasheet - Page 11

Photoelectric Sensors - Industrial CONVERGENT 2M DC CONN.

E3G-L77

Manufacturer Part Number
E3G-L77
Description
Photoelectric Sensors - Industrial CONVERGENT 2M DC CONN.
Manufacturer
Omron
Type
Photoelectric Sensorr
Series
E3Gr
Datasheets

Specifications of E3G-L77

Features
Dark ON
Height
68.5 mm
Length
47.8 mm
Maximum Operating Temperature
+ 55 C
Minimum Operating Temperature
- 25 C
Operating Supply Voltage
10 V to 30 V
Width
21 mm
Sensing Distance
2000 mm
Output Configuration
NPN or PNP
Output Current
100mA
Sensor Output
NPN/PNP
Supply Voltage Range Dc
10V To 30V
Sensor Housing
Rectangular
Sensor Input
Optical
Output Type
Transistor
Sensing Range Max
2m
Mounting Type
Bracket
Switch Terminals
Cable
Rohs Compliant
Yes
Sensing Method
Reflective, Diffuse
Sensing Object
Black Paper, Kodak® White Paper
Sensing Light
Infrared
Current - Supply
60mA
Voltage - Supply
10 V ~ 30 V
Package / Case
Module, Connector
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
E3G
J DISTANCE SETTING (TEACHING)
Select the most appropriate teaching method in reference to the following descriptions.
J NORMAL MODE
1. Normal One-point Teaching
La: Distance equivalent to threshold (a)
Lb: Distance equivalent to threshold (b)
Normal One-point Teaching
Normal Two-point Teaching
Application
Teaching
Setting method
Set threshold
Output ON range
Note: Perform normal one-point teaching with the background.
1.
2.
3.
4.
1.
2.
3.
4.
5.
E3G-L/ML
Operation
Set the mode selector to TEACH.
Set the NORMAL/ZONE mode selector to NORMAL.
Press the TEACH button with no sensing object
(i.e., teach the background). The teaching indicator (red) will turn ON.
Set the mode selector to RUN.
(Set to L-ON or D-ON mode.)
Operation
Set the mode selector to TEACH.
Set the NORMAL/ZONE mode selector to NORMAL.
Press the TEACH button with a sensing object located at the sensing
position. The teaching indicator (red) will turn ON.
Move the sensing object and press the TEACH button with the back-
ground.
If the teaching is successful, set the mode selector to RUN to complete
the teaching operation.
Set the E3G to light- ordark-ON mode with the mode selectoraccording
to the application.
If the teaching is not successful, change the set distance and object
sensing position and repeat two-point teaching from step 3.
ON
If the teaching is successful, the teaching indicator (green) will turn
ON.
Ifthe teaching isnotsuccessful, the teaching indicator(red) will start
to flash.
Threshold a
(La)
Teaching without sensing
objects (i.e., teaching the
background).
Normal one-point teaching
Press the TEACH button
with the background
object.
Threshold (a) is set to a
distance in front of the
background of 20% of the
background distance.
The output is ON between
the Sensor and La.
Background
2. Normal Two -point Teaching
E3G-L/ML
ON
Object
Setting a threshold in the
middle between the
background and sensing
object for operation.
Normal two-point teaching
Press the TEACH button
with the background object
and with the sensing
object.
Threshold (a) is set
approximately in the
middle between the
background and sensing
object.
The output is ON between
the Sensor and La.
Threshold a
(La)
Background
12
J ZONE MODE
Zone Teaching
Zone Teaching
Maximum Distance Setting (in Normal Mode)
E3G-L/ML
Note: Perform zone teaching with the background.
L-ON
D-ON
1.
2.
3.
4.
1.
2.
3.
4.
OFF
Detection of glossy objects
in front of the background.
Zone teaching
Press the TEACH button
with the background object
(conveyor, etc.).
Thresholds (a and b) are
set in the sensing distance
on condition that the
difference between these
thresholds are
approximately 10% of the
whole sensing distance.
The output is ON between
La and Lb.
Threshold
a (La)
ON
Set the mode selector to TEACH.
Set the NORMAL/ZONE mode selector to ZONE.
Press the TEACH button with the background.
Set the mode selector to RUN.
(Set to L-ON or D-ON mode.)
Set the mode selector to TEACH.
Set the NORMAL/ZONE mode selector to NORMAL.
Press the TEACH button for 3 s or more.
If the teaching is successful, set the mode selector to RUN to complete
the teaching operation.
(Set to L-ON or D-ON mode.)
Operation
Operation
Background
The teaching indicator (red) will turn ON first. Then the teaching
indicator (green) will turn ON.
The teaching indicator (red) will turn ON.
The teaching indicator (green) will turn ON in 3 s. This means that
teaching was successful.
OFF
ON
Threshold b (Lb)
OFF
ON
Setting the maximum
sensing distance of the
Sensor.
Maximum distance setting
(in normal mode)
Press the TEACH button
for longer than three
seconds.
The threshold is set so
that the stability indicator
will turn ON at
approximately 2 m if the
sensing object is white
paper.
The output is ON
whenever the sensing
object is located between
the Sensor and at a
distance of 2.2 m.
E3G

Related parts for E3G-L77