B6TS-04LT Omron, B6TS-04LT Datasheet - Page 11

Capacitance Touch Sensors Sensing IC

B6TS-04LT

Manufacturer Part Number
B6TS-04LT
Description
Capacitance Touch Sensors Sensing IC
Manufacturer
Omron
Series
-r
Type
Capacitiver
Datasheets

Specifications of B6TS-04LT

Sensitivity
-
Response Time
-
Interface
SPI
Channel Inputs
4 Key
Voltage - Supply
3 V ~ 5 V
Actuator Type
-
Package / Case
20-LSSOP (0.173", 4.40mm Width)
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
6.
0x00(ID)–0x19(CHYS3)
0x39(CHEN) –0x53(RHYS3)
0x00
0x01
0x02
0x03
0x04
0x05
0x06
:
0x0D
0x0E
0x0F
0x10
0x11
0x12
0x13
Command
Command code (Designation)
6.1
code
Commands
The commands and data used in serial communication are listed below:
The data comprises read only data (read) and read/write data (read/write). If serial communication is made to write
read only data, the operation will be invalid.
Some of the data are not accessible in some operation modes. If inaccessible data are read out, the read data is
indefinite. If inaccessible data are written, the data is ignored.
When writable data are written in this chip, the built-in register corresponding to each command is rewritten. Then, if
the normal measurement mode is entered, the chip can be operated with the written parameters (mode, etc.). In this
case, because only the built-in register is rewritten, the value in each register returns to its original value (value stored
in EEPROM) when power is turned off and on again.
To store the built-in register value in EEPROM, an EEPROM write command must be received. When an EEPROM
write command is received, the content of the register is stored in EEPROM.
List of commands
ID
BDATA
DCH0
DCH1
DCH2
DCH3
CREF0
CTHR0
CHYS0
CREF1
CTHR1
CHYS1
Desig-
nation
Chip ID
Detected result of each channel R
Ch0 measured value
Ch1 measured value
Ch2 measured value
Ch3 measured value
Current Ch0 reference value
Current Ch0 variation judged as
on
Current Ch0 hysteresis value
Current Ch1 reference value
Current Ch1 variation judged as
on
Current Ch1 hysteresis value
Description
Measured data
Parameter setting
Main function
(System reservation)
Read only
Read/write
R
R
R
R
R
R
R
R
R
R
R
Read/write
restriction
Access limit
Normal measurement
mode (in serial
communication mode)
Accessible
Inaccessible
1 channel 1 bit
Result of drift correction is reflected.
Result of drift correction is reflected.
Result of drift correction is reflected.
Result of drift correction is reflected.
Result of drift correction is reflected.
Result of drift correction is reflected.
Access restriction
Remark
Setup mode
Accessible

Related parts for B6TS-04LT