H-Q-5-KIT CONTACT CONNECTORS, H-Q-5-KIT Datasheet - Page 17

CONNECTOR KIT, TOP ENTRY, HQ5

H-Q-5-KIT

Manufacturer Part Number
H-Q-5-KIT
Description
CONNECTOR KIT, TOP ENTRY, HQ5
Manufacturer
CONTACT CONNECTORS
Series
EPIC HBSr
Datasheet

Specifications of H-Q-5-KIT

Connector Type
Rectangular
Gender
Plug, Socket
No. Of Contacts
5
No. Of Rows
2
Contact Gender
Male, Female
Connector Mounting
Cable Mount
Connector Shell Size
HQ 5
Contact
RoHS Compliant
Contact Termination
Crimp
Rohs Compliant
Yes
Technical
Technisches Vorwort / Technical Considerations / Préambule technique
Derating Curve:
The derating curve indicates the maximum current that can permanently and simultaneously flow through all connections if the
component is exposed to ambient temperatures below its upper limit temperature.
The upper limit temperature of a component is determined by the materials. The maximum temperature is calculated from the
ambient temperature and from heating due to current loading, it must not exceed the upper limit temperature of the component.
The derating of a component is not a constant value, but decreases hand-in-hand with the increase in component ambient tempe-
rature. Furthermore, current loading capacity is dependent upon geometry, the materials employed, the number of poles and the
conductor.
British and US comparative sizes for cables and lines
In the US, sizes of copper conductors for high current and telecommunication purposes are usually stated in AWG numbers. The
following comparisons apply:
AWG
500
350
250
4/0
3/0
2/0
1/0
Nr.
10
12
14
1
2
4
6
8
meter
17,96
15,03
12,70
11,68
10,40
Dia-
9,27
8,25
7,35
6,54
5,19
4,12
3,26
2,59
2,05
1,63
mm
C O N S I D E R A T I O N S
Section
107,2
mm
67,5
53,5
42,4
33,6
21,2
13,3
8,37
5,26
3,31
2,08
253
177
127
85
2
Since it is not advisable to use Heavy Duty connectors at
their loading limits, the base curve is reduced. If the loading
currents are reduced to 80%, then this produces the redu-
ced base curve in relation to the various connectors and
measurement uncertainties at which temperature measure-
ments are taken into account. Experience shows that the re-
duced base curve is a successful popular application.
NB: Only the reduced base curve is reproduced on the follo-
wing derating curves for inserts.
AWG
Nr.
16
18
20
22
24
26
28
30
32
34
36
38
40
42
44
meter
1,024
0,813
0,643
0,511
0,405
0,320
0,255
0,203
0,160
0,127
0,102
0,079
0,064
0,051
1,29
Dia-
mm
0,00811
0,00487
0,00317
0,00203
Section
0,0804
0,0507
0,0324
0,0200
0,0127
0,823
0,519
0,324
0,205
0,128
mm
1,31
2
29

Related parts for H-Q-5-KIT