CDB5461AU Cirrus Logic Inc, CDB5461AU Datasheet - Page 23

no-image

CDB5461AU

Manufacturer Part Number
CDB5461AU
Description
Eval Bd Sngl Phase Power/Energy
Manufacturer
Cirrus Logic Inc
Datasheets

Specifications of CDB5461AU

Main Purpose
Power Management, Energy/Power Meter
Embedded
Yes, MCU, 8-Bit
Utilized Ic / Part
CS5461A
Primary Attributes
1-Phase, Energy-to-Frequency Output
Secondary Attributes
GUI, USB, SPI, Microwire Interfaces
Processor To Be Evaluated
CS5461A, C8051F320
Interface Type
USB
Operating Supply Voltage
5 V
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant, Contains lead / RoHS non-compliant
Other names
598-1552
5.14 Commands
All commands are 8-bits in length. Any byte that is not listed in this section is invalid. Commands that write to regis-
ters must be followed by 3 bytes of data. Commands that read data can be chained with other commands (e.g., while
reading data, a new command can be sent which can execute during the original read). All commands except reg-
ister reads, register writes, and SYNC0 & SYNC1 will abort any currently executing commands.
5.14.1 Start Conversions
5.14.2 SYNC0 and SYNC1
The serial port can be initialized by asserting CS or by sending three or more consecutive SYNC1 commands fol-
lowed by a SYNC0 command. The SYNC0 or SYNC1 can also be sent while sending data out.
5.14.3 Power-Up/Halt
If the device is powered-down, Power-Up/Halt will initiate a power on reset. If the part is already powered-on, all
computations will be halted.
5.14.4 Power-down and Software Reset
To conserve power the CS5461A has two power-down states. In stand-by state all circuitry, except the analog/digital
clock generators, is turned off. In the sleep state all circuitry, except the instruction decoder, is turned off. Bringing
the CS5461A out of sleep state requires more time than out of stand-by state, because of the extra time needed to
re-start and re-stabilize the analog oscillator.
DS661F2
Initiates acquiring measurements and calculating results. The device has three modes of acquisition.
B7
B7
B7
B7
1
1
1
1
SYNC
C[3:2]
S[1:0]
B6
B6
B6
B6
1
1
0
0
B5
B5
B5
B5
1
1
1
0
00 = Perform a single computation cycle
01 = Not Used
10 = Perform continuous computation cycles
11 = Perform continuous computation cycles with APF enabled on the other channel
0 = Last byte of a serial port re-initialization sequence.
1 = Used during reads and serial port initialization.
00 = Software Reset
01 = Halt and enter stand-by power saving state. This state allows quick power-on
10 = Halt and enter sleep power saving state.
11 = Reserved
Modes of acquisition/measurement
Power-down state
B4
B4
B4
B4
S1
0
1
0
B3
C3
B3
B3
B3
S0
1
0
B2
C2
B2
B2
B2
1
0
0
B1
B1
B1
B1
0
1
0
0
SYNC
B0
B0
B0
B0
0
0
0
CS5461A
23

Related parts for CDB5461AU