H3CR-F8 AC/DC24 Omron, H3CR-F8 AC/DC24 Datasheet - Page 21

TIMER REPEAT CYCLE

H3CR-F8 AC/DC24

Manufacturer Part Number
H3CR-F8 AC/DC24
Description
TIMER REPEAT CYCLE
Manufacturer
Omron
Series
H3CR-Fr
Datasheet

Specifications of H3CR-F8 AC/DC24

Rohs Compliant
YES
Relay Type
Integrated
Function
Repeat Cycle
Circuit
DPDT (2 Form C)
Delay Time
0.05 Sec ~ 30 Hrs
Output Type
Mechanical Relay
Contact Rating @ Voltage
5A @ 250VAC
Voltage - Supply
24VAC/DC
Mounting Type
Socket
Termination Style
8 Pin Socketable
Timing Adjustment Method
Hand Dial
Timing Initiate Method
Input Voltage
Contact Configuration
DPDT
Timing Adjustment
Knob
Relay Mounting
Panel
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
H3CR-F8-AC/DC24
H3CR-F8-AC/DC24
H3CRF8ACDC24
Z2382
Safety Precautions for All Timers
Refer to the Safety Precautions for individual Timers for precautions specific to each Timer.
■ Precautions for Safe Use
Operating Environment
• Use the Timer within the ratings specified for ambient operating
• Store the Timer with the specified temperature range for each
• Use the Timer within the performance specified for water and oil
• Do not use the Timer in locations subject to shock and vibration.
• Do not use the Timer in locations subject to excessive dust,
• Do not use organic solvents (such as paint thinner or benzine),
• Separate the input devices, input wiring, and Timer as far as
• When using the Timer in environments subject to large amounts of
• Do not remove the external case from the Timer.
• Do not use the Timer in locations where condensation may occur
• The life of internal parts may be reduced if Timers are mounted in
• Resin and rubber parts (e.g., rubber packing) may deteriorate,
The following Timers contain lithium batteries that are
not explosion proof.
1. Timers with Built-in Batteries: H5L
2. Timers with Replaceable Batteries: Y92S-20 (for H5CN-M)
The following Timers contain lithium batteries that are
explosion proof.
temperature and ambient operating humidity for each model.
model. If the Timer has been stored at a temperature of less than
−10°C, allow the Timer to stand at room temperature for at least 3
hours before using it.
exposure for each model.
Long-term usage in such locations may damage the Timer due to
stress.
Magnetic contactors generate a shock of 1,000 to 2,000 m/s
switching a load. When mounting to DIN Track, separate magnetic
contactors from the Timer so that the Timer is not subjected to
vibration and shock. Use anti-vibration rubber.
corrosive gases, or direct sunlight.
strong alkalis, or strong acids because they will damage the
external finish of the Timer.
possible from sources of noise and power lines carrying noise.
static electricity (e.g., pipes carrying molding materials, powders, or
fluid materials), separate the Timer as far as possible from the
sources of static electricity.
due to high humidity or sudden temperature changes.
Condensation inside the Timer may result in malfunction or
damage to Timer elements.
close proximity to each other.
shrink, or harden depending on the operating environment (e.g.,
subjected to corrosive gases, ultraviolet light, or high
temperatures). We recommend periodic inspection and
replacement.
The Timer contains a lithium battery, which may occasionally
ignite or rupture. Do not disassemble, deform under pressure,
heat to 100°C or higher, or incinerate the Timer.
The battery may occasionally rupture, ignite, or leak fluid. Do
not short the positive and negative terminals. Do not charge,
disassemble, deform under pressure, or throw the battery into a
fire. If a non-specified battery is used, the battery may leak fluid
or rupture, occasionally resulting in equipment failure or minor
injury. Use only the specified battery.
Timers with Built-in Batteries: H5BR, H5AN-4DM, H5S, H5F, and
The Timer contains a lithium battery, which may occasionally
ignite or rupture. Do not disassemble, deform under pressure,
heat to 100°C or higher, or incinerate the Timer.
http://www.ia.omron.com/
!WARNING
!CAUTION
H4KV
2
when
• Normal operation may not be possible in locations subject to
Power Supply
• Be sure that the voltage applied is within the specified range,
• Install a switch or circuit breaker that allows the operator to
• Maintain voltage fluctuations
• Use a commercial power supply for the power supply voltage input
• The Timers listed below cannot be directly turned ON and OFF by
• Install protective measures (such as earth leakage breakers, wiring
sulfidizing gas, such as in sewer systems or waste incinerators.
OMRON does not market any Timers or other control devices for
operation in atmospheres containing sulfidizing gas. Seal the Timer
so that sulfidizing gas will not enter it. If sealing is not possible,
OMRON does provide special Timers with improved resistance to
sulfidizing gas. Ask your OMRON representative for details.
otherwise the internal elements of the Timer may be damaged.
immediately turn OFF the power, and label it to clearly indicate its
function.
in the power supply within
the specified range.
to models with AC inputs.
Inverters with an output frequency of 50/60 Hz are available, but
the rise in the internal temperature of the Timer may result in
ignition or burning. Do not use an inverter output for the power
supply of the Timer.
using an AC 2-wire proximity sensor to turn the Timer's power
supply ON and OFF.
Use the following countermeasure when using an AC 2-wire
proximity sensor with the Timer. (The power supply circuit in the
Timer uses half-wave rectification. Only a half AC wave is supplied
to the proximity sensor, which may cause operation to be unstable.)
Applicable Models
H3Y, H3YN, H3RN, H3CA-8, RD2P, and H3CR(-A, -A8, -AP, -F, and
-G)
Countermeasure
Wire through a relay and use the relay contacts to turn the power
supply ON and OFF.
Confirm the stability of operation after making the connections.
breakers, or fuses) on the power supply side according to any
applicable laws or regulations.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
Voltage Range
Allowable
C-1

Related parts for H3CR-F8 AC/DC24