Specifications of N6752A

Power Supply Output Type
Variable
No. Of Outputs
1
Output Voltage
50V
Output Current
10A
Power Rating
100W
Input Voltage
100V AC To 240V AC
Length
596.9mm
Width
432.5mm
Height
44.45mm
Lead Free Status / RoHS Status
na
“SYSTem:COMMunicate:RLState
RWLock” must be used to lock
out the front panel. Please see
the N6700 User’s Guide for
more details.
Local (Front Panel)
Both the 662xA and N6700A/B
have front panel controls and
display. The 662xA’s front
panel control has individual
buttons for each feature along
with a numerical keypad. The
N6700A/B eliminates most of
these buttons, but has much
more capable control from the
front panel. It has an extensive
menu system with a few keys
for quick, one-button access
as well as navigational keys
and a numerical keypad. The
N6700A/B is also capable of
displaying all four channels
voltage and current at the
same time, while the 662xA
can only show one channel
at a time.
Comparison of 662xA Commands
and N675xA and N676xA Modules
Compatibility Commands
There are three general areas
of differences between the
662xA’s commands and the
N67xxA modules compatibility
commands—IEEE 488.2 Syntax,
Status Reporting, and Model
Specific Limits. In addition,
there are specific functions
that are not implemented
or are different.
IEEE 488.2 Syntax
Space Separator I
The N67xxA Modules will
not allow a space separator
between numbers.
Example:
“ISET 1 0.5” and “ISET 1, 0.5”
662xA: Both commands are
accepted and processed with
the same results.
N67xxA Modules: Only “ISET 1,
0.5” is accepted. “ISET 1 0.5”
will result in an error (-103,
“Invalid separator”).
Space Separator II
A space is needed between
the command and the
channel number.
Example:
“ISET1,0.5” and “ISET 1,0.5”
662xA: Both commands are
accepted and processed with
the same results.
N67xxA Modules: Only “ISET
1,0.5” is accepted. ISET1,0.5
will result in an error (-103.
“Invalid separator”).
9
Queries and Readback
Multiple Queries without
Continuous Readback
Sending a second query to
an N67xxA module without
reading the response to the
first will generate an error.
Example:
662xA: Readback will return
the value of the “VSET? 1”
query without an error.
N67xxA Modules: Readback
will return the value of the
“VSET? 1” query and will error
(-410, “Query INTERRUPTED”).
Multiple Queries with
Partial Readback
An N67xxA Module will
not allow a user to query
information, read back only
a portion of the information
(a few characters), send another
command, and finish reading
back the remaining information
from the original query.
Example: ISET 1, 1
662xA: Partial readback will
return a few characters.
Remaining readback will return
the remaining characters along
with the value “1”, from the
“ISET? 1” query, without error.
ISET? 1
<partial readback>
ISET 1, 0.5
<readback remaining>
ISET? 1
VSET? 1
<readback>