N6752A AGILENT TECHNOLOGIES, N6752A Datasheet
N6752A
Specifications of N6752A
Related parts for N6752A
N6752A Summary of contents
Page 1
... N6761A (50 W) and N6762A (100 W) Precision output modules. • “N67xxA Module” refers only to the features and characteris- tics of the N6751A, N6752A, N6761A, and N6762A output modules and does not include the N674x, N673x, etc. • “662xA” refers to the features and characteristics of the 6621A— ...
Page 2
... Mainframe with 2—N6752A 100 W Autoranging Output Modules Previously available as N6722A 1—N6700A/B Mainframe with 2—N6751A 50 W Autoranging Output Modules 1—N6752A 100 W Autoranging Output Module Previously available as N6723A 1—N6700A/B Mainframe with 4—N6751A 50 W Autoranging Output Modules Previously available as N6724A 1—N6700A/B Mainframe with 1— ...
Page 3
Option and Accessory Selection Some features that were options on the 662xA are now standard on the N6700A/B. at Table 2 right provides a list of options for the 662xA and how they correspond to the N6700A/B. Some options are ...
Page 4
Option 750, External Relay Control and RI/DFI (RI latches) The 662xA with Option 750 has an 8-pin port dedicated to the control four external relays and a 4-pin port dedicated to RI/DFI. The N6700A mainframe comes standard ...
Page 5
... W Low and High Voltage out- puts in the 662xAs, can output any combination of 50 Watts or 5 The N6752A is the only exception to this rule. It can produce 100 W from 12 V/8. V/2 A. Between 8.33 A and 10 A, the N6752A’s output power derates from 100 ...
Page 6
On the N67xxA modules, the OV trip point can be programmed all 50 W and 100 W output modules. When overvoltage protection is enabled, the power supply will turn off its output if the output ...
Page 7
Current Sink (Downprogramming) Capability • 40 W/80 W High/Low Voltage Outputs current sink limits are fixed approximately 10% higher than the maximum current source limits for a given operating voltage at any voltage above 2.5 V. • Precision ...
Page 8
Transient Response • 40 W/80 W High/Low Voltage Outputs: 75 µs maximum to recover to within nominal value following a load change within the range 300 mA to full load for low voltage units, and 150 mA ...
Page 9
RWLock” must be used to lock out the front panel. Please see the N6700 User’s Guide for more details. Local (Front Panel) Both the 662xA and N6700A/B have front panel controls and display. The 662xA’s front panel control has ...
Page 10
N67xxA Modules: Readback will not return any information and errors, such as -410,“Query INTERRUPTED” and -420, “Query UNTERMI- NATED” will be reported. Multiple, Semicolon- Separated Queries The 662xA overwrites any previous unread query responses. The N6700A, however, can respond to ...
Page 11
Status Reporting Status, Accumulated Status, Mask, and Fault Registers below lists the bit Table 5 assignments for the Status, Accumulated Status, Mask, and Fault Registers and how they translate between the 662xA and the N67xxA modules. The “-CC” bit will ...
Page 12
N675xA Modules: The automatic setting adjust- ment done in the 662xA when the range changes will not occur because longer necessary due to the autoranging capabil- ity of the N675xA. Since there is no range switching, the ...
Page 13
These models have 11 internal registers, which have the following characteristics: • Register 0 is recalled automatically at power-on. • Register 0 stores: VSET, VRSET, ISET, IRSET, OVSET, OCP, DLY, and MASK for all outputs. • ...
Page 14
Mechanical/Physical Size The overall physical size of the N6700A/B mainframe is much smaller than the 662xA power supply. Please see at Table 8 right. Positive deltas indicate smaller or lighter. Color The 662xA’s front panel color was Mint Gray prior ...
Page 15
N6700A/B mainframe. The N6700A/B can only be rack mounted using Option 908 (p/n N6700-60009). No other means of rack mounting should be used due to airflow and height restrictions. For ...
Page 16
Appendix A 662xA to N67xx Comparison Sheet Current Model Specifications 40 W Low Voltage (at 0° to 55°C unless otherwise specified) Output Output Power Low range volts, amps High range 0 to ...
Page 17
... Any combination of the specified Voltage and Current that is less than or equal to the specified power rating. Please see 50 W and 100 W Comparison Graphs for graphical representations of this. 10 100 W from 12 V/8. V/2 A. Between 8.33 A and 10 A, the N6752A’s output power derates from 100 Please see 100 W Comparison Graph for a graphical representation of this High Performance 100 W High Performance ...
Page 18
... Rectangular Output vs. Autoranging Output Graph (50 W Comparison Graph High and Low Voltage Output vs N6751A High Performance Autoranging DC Power Module Rectangular Output vs. Autoranging Output Graph (100 W Comparison Graph High and Low Voltage Output vs. N6752A 100 W High Performance Autoranging DC Power Module Autoranging DC Power Module 40 W Low Volt Output (high range) ...
Page 19
Appendix B Figure 1b. N6700A/B Dimensions and Airflow Figure 1a. 662xA Dimensions and Airflow Figure 2a. 662xA Output Connectors Figure 2b. N67xxA Module Output Connectors ...
Page 20
... Agilent N6700 Series visit: http://www.agilent.com/find/n6700 Agilent Technologies’ Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need ...