LIMIT SWITCH, SPDT-1NO/1NC

D4NH3132H

Manufacturer Part Number
D4NH3132H
Description
LIMIT SWITCH, SPDT-1NO/1NC
Manufacturer
Omron
Series
D4NHr
Datasheet

Specifications of D4NH3132H

Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
2.5A
Switch Terminals
Screw
Contact Configuration
SPDT-1NO / 1NC
Circuitry
SPDT-1NO/1NC
Lead Free Status / RoHS Status
na
Structure and Nomenclature
Structure
Contact Form
Note: 1. Terminals are numbered according to EN50013. Contact forms are according to EN60947-5-1.
* MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally open
Cover
The cover, with a hinge on its lower part, can be
opened by removing the screw of the cover, which
ensures ease of maintenance and wiring.
Note: The housing and head of the D4NH are made of resin. Use D4BS
The built-in switch has a direct opening mechanism
that forcibly separates the NC contact even when
there is contact deposit.
Built-in Switch
contact (NO) closes.
D4NH-@C@
D4NH-@D@
D4NH-@A@
D4NH-@B@
D4NH-@E@
D4NH-@F@
Guard Closed
Model
2. MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally
Safety-door Switches for applications requiring safety door switches of tough,
high-sealing, or oil-resistant construction.
When the guard is opened, the cam that is directly coupled to
the shaft rotates to press the Switch in the direction shown by
the (vertical) arrow. This action separates the contacts to stop
the machine.
open contact (NO) closes.
(D4NH-@@BC)
Forced
separation
of NC
contacts
When
opening
the guard
1NC/1NO MBB *
2NC/1NO MBB *
Cam
1NC/1NO
2NC/1NO
Contact
2NC
3NC
Guard Open
Contact form
11
33
11
31
11
21
33
11
21
31
11
33
11
21
33
Zb
Zb
Zb
Zb
Zb
Zb
12
34
12
32
12
22
34
12
22
32
12
34
12
22
34
11-12
33-34
11-12
31-32
11-12
21-22
33-34
11-12
21-22
31-32
11-12
33-34
11-12
21-22
33-34
Operating pattern
Stroke
Stroke
Stroke
Stroke
Stroke
Stroke
Arm Lever
The joint between the shaft and
arm lever is formed with
form-lock construction which
remains secure even when the
screw becomes loose.
Conduit
A wide variety of conduits is available.
The arm lever is mounted upwards in the center
position before shipping. To change the position,
loosen the arm lever mounting screw, dismount
the arm lever, and mount the arm lever in the left
or right position.
Head
The head can be mounted in four directions.
Note: M12 connector types are not available for
ON
ON
ON
ON
ON
ON
Size
Pg13.5
G1/2
1/2-14NPT
M20
M12 Connector
Switches with three contacts.
Only NC contacts 11-12 have a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
Only NC contacts 11-12 and
31-32 have a certified direct
opening mechanism.
The terminals 11-12 and 31-32
can be used as unlike poles.
Only NC contacts 11-12 and
21-22 have a certified direct
opening mechanism.
The terminals 11-12, 21-22, and
33-34 can be used as unlike
poles.
Only NC contacts 11-12, 21-22,
and 31-32 have a certified
direct opening mechanism.
The terminals 11-12, 21-22, and
31-32 can be used as unlike
poles.
Only NC contacts 11-12 have a
certified direct opening
mechanism.
The terminals 11-12 and 33-34
can be used as unlike poles.
Only NC contacts 11-12 and
21-22 have a certified direct
opening mechanism.
The terminals 11-12, 21-22 and
33-34 can be used as unlike poles.
Box
1-conduit
Yes
Yes
Yes
Yes
Yes
Remarks
2-conduit
D4NH
Yes
Yes
Yes
Yes
---
4

Related parts for D4NH3132H