D4NH3132H Omron, D4NH3132H Datasheet

LIMIT SWITCH, SPDT-1NO/1NC

D4NH3132H

Manufacturer Part Number
D4NH3132H
Description
LIMIT SWITCH, SPDT-1NO/1NC
Manufacturer
Omron
Series
D4NHr
Datasheet

Specifications of D4NH3132H

Contact Voltage Ac Max
240V
Contact Voltage Dc Max
250V
Contact Current Ac Max
10A
Contact Current Dc Max
2.5A
Switch Terminals
Screw
Contact Configuration
SPDT-1NO / 1NC
Circuitry
SPDT-1NO/1NC
Lead Free Status / RoHS Status
na
Compact, Plastic-body Safety-door
Hinge Switch Designed for Saving
Space in Machines and Other
Equipment
Model Number Structure
Model Number Legend
1. Conduit size
Application Examples
Shaft Actuator
D4NH-@@@
• Lineup includes three contact models with 2NC/1NO and
• M12-connector models are available, saving on labor and
• Standardized gold-clad contacts provide high contact
Safety-door Hinge Switch
D4NH
3NC contact forms in addition to the previous contact forms
1NC/1NO, and 2NC. Models with MBB contacts are also
available.
simplifying replacement.
reliability. Can be used with both standard loads and
microloads.
1: Pg13.5 (1-conduit)
2: G1/2 (1-conduit)
3: 1/2-14NPT (1-conduit)
4: M20 (1-conduit)
5: Pg13.5 (2-conduit)
6: G1/2 (2-conduit)
7: 1/2-14NPT (2-conduit)
8: M20 (2-conduit)
9: M12 connector (1-conduit)
Be sure to read the “Safety Precautions” on page 9 and the
“Precautions for All Safety Door Switches”.
1 2 3
(Protective Door Safety Measures)
Arm Lever Actuator
2. Built-in Switch
3. Actuator
A: 1NC/1NO (slow-action)
B: 2NC (slow-action)
C: 2NC/1NO (slow-action)
D: 3NC (slow-action)
E: 1NC/1NO (MBB contact) (slow-action)
F: 2NC/1NO (MBB contact) (slow-action)
AS:Shaft
BC:Arm lever
Note: Contact your sales representative for details on
models with safety standard certification.
CSM_D4NH_DS_E_4_1
1

Related parts for D4NH3132H

D4NH3132H Summary of contents

Page 1

Safety-door Hinge Switch D4NH Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment • Lineup includes three contact models with 2NC/1NO and 3NC contact forms in addition to the previous contact forms 1NC/1NO, and 2NC. ...

Page 2

... Ordering Information List of Models Switches Consult with your OMRON representative when ordering any models that are not listed in this table. Actuator 1-conduit Shaft 2-conduit 1-conduit Arm lever 2-conduit Actuator 1-conduit Shaft 2-conduit 1-conduit Arm lever 2-conduit Note recommended that M20 be used for Switches to be exported to Europe and 1/2-14NPT be used for Switches to be exported to North American countries ...

Page 3

... Rated operating voltage (U Note: Use fuse type that conforms to IEC60269 as a short-circuit protection device. This fuse is not built into the Switch. UL/CSA (UL508, CSA C22.2 No. 14) A300 File No. Ask your OMRON Rated Carry current representative for voltage information on certified models. 120 VAC ...

Page 4

Structure and Nomenclature Structure (D4NH-@@BC) Guard Open Guard Closed Cam Forced separation of NC contacts When opening the guard When the guard is opened, the cam that is directly coupled to the shaft rotates to press the Switch in the ...

Page 5

Direct Opening Mechanism 1NC/1NO Contact (Slow-action) Fixed contact (NC) Contact spring Movable contact Fixed contact (NO) Plunger Return spring Conforms to EN60947-5-1 Direct Opening (Only NC Contact has a direct opening mechanism.) When contact welding occurs, the contacts are separated ...

Page 6

Dimensions and Operating Characteristics Shaft Type with 1 Conduit D4NH-1@AS D4NH-2@AS D4NH-3@AS D4NH-4@AS D4NH-9@AS * Red 20.5 × 20.5 18 9± 0.2 Black 20± 0.1 47± 0.2 22± 0.1 55 22± 0.2 31max. Shaft Type with 2 Conduits D4NH-5@AS D4NH-6@AS ...

Page 7

Arm Lever Type with 1 Conduit D4NH-1@BC D4NH-2@BC D4NH-3@BC D4NH-4@BC D4NH-9@ 80± 1 Red 29± Black 18 9± 0.2 47± 0.2 55 Arm Lever Type with 2 Conduits D4NH-5@BC D4NH-6@BC D4NH-7@BC D4NH-8@ 29± Red 18 Black ...

Page 8

Application Examples of Arm Lever Use When Installing at the Center The arm lever is set for center installation at the time of shipment. Note: Install the arm lever so that it will not rotate more than 90°. (Be sure ...

Page 9

Safety Precautions Refer to the “Precautions for All Switches” and “Precautions for All Safety Door Switches”. !CAUTION Electric shock may occasionally occur. Do not use metal connectors or metal conduits. Precautions for Safe Use • Do not use the Switch ...

Page 10

... Connector Type Pin No. (Terminal No.) • Applicable socket: XS2F-D421 series (OMRON). • Refer to the Connector Catalog for details on socket pin numbers and lead wire colors. Socket Tightening (Connector Type) • Turn the socket connector screws by hand and tighten until no space remains between the socket and the plug. ...

Page 11

Recommended Connectors Use connectors with screws not exceeding 9 mm, otherwise the screws will protrude into the case interior, interfering with other components in the case. The connectors listed in the following table have connectors with thread sections not exceeding ...

Page 12

Production Discontinuation Following the release of the D4NH, production of the D4DH was discontinued. Date of Production Discontinuation Production of the D4DH Series was discontinued as of the end of March 2006. Recommended Substitute Products Use the D4NH-series Switches, which ...

Page 13

... Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS ...