CV500CN224 Omron, CV500CN224 Datasheet - Page 9

no-image

CV500CN224

Manufacturer Part Number
CV500CN224
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500CN224

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Connecting an IBM PC/AT or Compatible with RS-232C Cable
Motion Control Modules
CPU Unit
Serial
Communications
Board/Unit
CS1-series
Operating modes
Manual
Manual
8
Applicable CPU Units
Overview of Operations
PC
Unit
CS1H-CPUjj
CS1G-CPUjj
Jogging
Handle feed
Deceleration stop
Manual origin search
Manual origin return
Forced origin
Absolute origin setting
Servo-lock
Servo-unlock
Electronic gear function
CPU Unit model
RS-232C
(9-pin D-sub
female)
RS-232C
(9-pin D-sub
female)
Item
Port on Unit
number
IBM PC/.AT
or compatible
Computer
CS1W-MC221: 32 Units (each Unit requires 30 words equivalent to 3 unit
numbers; unit numbers 0 to 93)
CS1W-MC421: 19 Units (each Unit requires 50 words equivalent to 5 unit
numbers; unit numbers 0 to 91)
The current consumption must be within the allowable range for the
Power Supply Unit.
Total number of MC Modules that can be mounted on CPU Racks
The following two modes are available.
Manual Mode: Operation according to CPU Unit memory area or commands from
Teaching Box.
Automatic Mode: Operation according to commands in G-language program.
Moves axes continuously by manual operation.
Moves axes by MPG.
Decelerates to a stop according to command.
Searches for mechanical origin. (Origin search is possible in either an incremental or
absolute encoder system.)
Moves to origin in reference coordinate system.
Forcibly sets the present position to 0 to establish it as the origin. (In an absolute
encoder system, only the present position of the MC Module will be set to 0.)
Sets the origin for an absolute encoder.
Creates a position loop and turns ON the operation command output to the Servo
Drive, while simultaneously releasing the brake. When an absolute encoder is used,
the absolute position is read before the servo-lock is applied.
Releases the position loop and applies the brake, and simultaneously turns OFF the
operation command output to the Servo Drive. Servo-unlock can be executed even in
Automatic Mode.
A fixed ratio (numerator and denominator) can be applied to input pulses, and output
to the Servo Motor driver.
9-pin D-sub
male
computer
Port on
and Expansion I/O Racks
Host Link
Host Link
communications
mode (network)
Serial
Contents
C200HS-CN220-EU
C200HS-CN220-EU
Model numbers
Product Specifications
2 m
2 m
Length
None
Unit location
restrictions
---
Remarks