CV500CN224 Omron, CV500CN224 Datasheet - Page 21
CV500CN224
Manufacturer Part Number
CV500CN224
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet
1.CV500CN224.pdf
(26 pages)
Specifications of CV500CN224
Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
DRV X-Y and Z-U Connectors
The DRV connectors are used primarily to connect Servo Drives. The DRV X-Y connector is for the X and Y axes, and the DRV Z-U connector is
for the Z and U axes.
Special drive cables, which are sold separately, are available for OMRON W and U-series Servo Drives.
Snap-on Connectors
Motion Control Modules
20
CS1W-MC221
DRV Connector Wiring
Connector: 10136-3000VE (provided with the Unit, manufactured by Sumitomo 3M)
Case: 10336-52F0-008 (provided with the Unit, manufactured by Sumitomo 3M)
CS1W-MC221
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
Pin
+24 V
DC GND
XALM
XRUN
XALMRS
---
---
XSGND
XSOUT
X-GND
X-A
X-A
X-B
X-B
X-Z
X-Z
XOUT
XAGND
+F24V
FDC GND
YALM
YRUN
YALMRS
---
---
YSGND
YSOUT
Y-GND
Y-A
Y-A
Y-B
Y-B
Y-Z
Y-Z
YOUT
YAGND
Symbol
24 VDC input
24 VDC input ground
X-axis alarm input
X-axis run output
X-axis alarm reset
output
---
---
X-axis SEN signal
ground
X-axis SEN signal
output
X-axis feedback ground
X-axis phase A input
X-axis phase A input
X-axis phase B input
X-axis phase B input
X-axis phase Z input
X-axis phase Z input
X-axis speed control
X-axis speed control
ground
24 VDC output
24 VDC output ground
Y-axis alarm input
Y-axis run output
Y-axis alarm reset
output
---
---
Y-axis SEN signal
ground
Y-axis SEN signal
output
Y-axis feedback ground
Y-axis phase A input
Y-axis phase A input
Y-axis phase B input
Y-axis phase B input
Y-axis phase Z input
Y-axis phase Z input
Y-axis speed control
Y-axis speed control
ground
Name
External power supply’s 24-VDC
input (for the X-Y axes)
External power supply’s 24-VDC
ground (for the X-Y axes)
Drive alarm input for the X-axis
Drive run output for the X-axis
Reset output for the X-axis’s driver
alarm.
Not used.
Not used.
SEN signal ground for the X-axis
SEN signal output for the X-axis
(absolute encoder driver)
Feedback ground for the X-axis
Phase A feedback input for the X-axis
Phase A feedback input for the X-axis
Phase B feedback input for the X-axis
Phase B feedback input for the X-axis
Phase Z feedback input for the X-axis
Phase Z feedback input for the X-axis
Speed control voltage to the X-axis
driver
Ground for the X-axis’s speed control
voltage
24-VDC input to the driver (for the
X-Y axes)
Ground for 24-VDC outputs (for the
X-Y axes)
Drive alarm input for the Y-axis
Drive run output for the Y-axis
Reset output for the Y-axis’s driver
alarm.
Not used.
Not used.
SEN signal ground for the Y-axis
SEN signal output for the Y-axis
(absolute encoder driver)
Feedback ground for the Y-axis
Phase A feedback input for the Y-axis
Phase A feedback input for the Y-axis
Phase B feedback input for the Y-axis
Phase B feedback input for the Y-axis
Phase Z feedback input for the Y-axis
Phase Z feedback input for the Y-axis
Speed control voltage to the Y-axis
driver
Ground for the Y-axis’s speed control
voltage
Product Specifications
Function