CV500CN224 Omron, CV500CN224 Datasheet - Page 21

no-image

CV500CN224

Manufacturer Part Number
CV500CN224
Description
Programmable Logic Controller
Manufacturer
Omron
Datasheet

Specifications of CV500CN224

Peak Reflow Compatible (260 C)
No
Leaded Process Compatible
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
DRV X-Y and Z-U Connectors
The DRV connectors are used primarily to connect Servo Drives. The DRV X-Y connector is for the X and Y axes, and the DRV Z-U connector is
for the Z and U axes.
Special drive cables, which are sold separately, are available for OMRON W and U-series Servo Drives.
Snap-on Connectors
Motion Control Modules
20
CS1W-MC221
DRV Connector Wiring
Connector: 10136-3000VE (provided with the Unit, manufactured by Sumitomo 3M)
Case: 10336-52F0-008 (provided with the Unit, manufactured by Sumitomo 3M)
CS1W-MC221
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
Pin
+24 V
DC GND
XALM
XRUN
XALMRS
---
---
XSGND
XSOUT
X-GND
X-A
X-A
X-B
X-B
X-Z
X-Z
XOUT
XAGND
+F24V
FDC GND
YALM
YRUN
YALMRS
---
---
YSGND
YSOUT
Y-GND
Y-A
Y-A
Y-B
Y-B
Y-Z
Y-Z
YOUT
YAGND
Symbol
24 VDC input
24 VDC input ground
X-axis alarm input
X-axis run output
X-axis alarm reset
output
---
---
X-axis SEN signal
ground
X-axis SEN signal
output
X-axis feedback ground
X-axis phase A input
X-axis phase A input
X-axis phase B input
X-axis phase B input
X-axis phase Z input
X-axis phase Z input
X-axis speed control
X-axis speed control
ground
24 VDC output
24 VDC output ground
Y-axis alarm input
Y-axis run output
Y-axis alarm reset
output
---
---
Y-axis SEN signal
ground
Y-axis SEN signal
output
Y-axis feedback ground
Y-axis phase A input
Y-axis phase A input
Y-axis phase B input
Y-axis phase B input
Y-axis phase Z input
Y-axis phase Z input
Y-axis speed control
Y-axis speed control
ground
Name
External power supply’s 24-VDC
input (for the X-Y axes)
External power supply’s 24-VDC
ground (for the X-Y axes)
Drive alarm input for the X-axis
Drive run output for the X-axis
Reset output for the X-axis’s driver
alarm.
Not used.
Not used.
SEN signal ground for the X-axis
SEN signal output for the X-axis
(absolute encoder driver)
Feedback ground for the X-axis
Phase A feedback input for the X-axis
Phase A feedback input for the X-axis
Phase B feedback input for the X-axis
Phase B feedback input for the X-axis
Phase Z feedback input for the X-axis
Phase Z feedback input for the X-axis
Speed control voltage to the X-axis
driver
Ground for the X-axis’s speed control
voltage
24-VDC input to the driver (for the
X-Y axes)
Ground for 24-VDC outputs (for the
X-Y axes)
Drive alarm input for the Y-axis
Drive run output for the Y-axis
Reset output for the Y-axis’s driver
alarm.
Not used.
Not used.
SEN signal ground for the Y-axis
SEN signal output for the Y-axis
(absolute encoder driver)
Feedback ground for the Y-axis
Phase A feedback input for the Y-axis
Phase A feedback input for the Y-axis
Phase B feedback input for the Y-axis
Phase B feedback input for the Y-axis
Phase Z feedback input for the Y-axis
Phase Z feedback input for the Y-axis
Speed control voltage to the Y-axis
driver
Ground for the Y-axis’s speed control
voltage
Product Specifications
Function