3UG4622-1AW30 SIEMENS, 3UG4622-1AW30 Datasheet - Page 60

RELAY, MONITOR, 22.5MM

3UG4622-1AW30

Manufacturer Part Number
3UG4622-1AW30
Description
RELAY, MONITOR, 22.5MM
Manufacturer
SIEMENS
Series
3UG46r
Datasheet

Specifications of 3UG4622-1AW30

Contact Configuration
SPCO
Power Consumption
4VA
Supply Voltage Max
240VAC
Contact Current Max
3A
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
230V
External Depth
86mm
Coil Frequency Max
60Hz
Coil Operating Frequency Min
50Hz
3RT19 timing relays for mounting to contactors
Technical specifications
According to IEC 61 812-1/DIN VDE 0435 Part 2021
Type
Rated insulation voltage
Pollution degree 3
Overvoltage category III to DIN VDE 0110
Operating range of excitation
Rated power
• Power consumption at 230 V AC, 50 Hz
Rated operational currents I
• AC-14 and DC-13
• AC-15 at 230 V AC, 50 Hz
• DC-13 at 24 V
• DC-13 at 110 V
• DC-13 at 230 V
DIAZED fuse
gL/gG operational class
Switching frequency
• When loaded with I
• When loaded with 3RT1016 contactor, 230 V AC
Recovery time
Minimum ON period
Residual current
(two-wire)
Voltage drop
with conducting output
Short-time loading capacity
Setting accuracy
with reference to upper limit of scale
Repeat accuracy
Mechanical endurance
Permissible ambient temperature
Degree of protection
acc. to EN 60529
Connection of conductors
Terminal screw
Tightening torque
Permissible mounting position
Shock resistance
Half sine acc. to IEC 60068-2-27
Vibration resistance
acc. to IEC 60068-2-6
EMC tests
acc. to basic specification
Overvoltage protection
7/60
3RP, 7PV Timing Relays
Siemens LV 1 T · 2006
e
230 V AC
e
Operating cycles
During operation
During storage
Solid
Finely stranded with end sleeve
Solid or stranded
Varistor
V AC
W
VA
A
A
A
A
A
A
1/h
1/h
ms
ms
mA
VA
A
°C
°C
mm²
mm²
AWG
Nm
g/ms
Hz/mm
3RT19 16-2C
3RT19 16-2D
3RT19 26-2C
3RT19 26-2D
300
0.8...1.1 x U
0.95 ... 1.05 times rated frequency
1
1
0.3 for 3RT1916
0.5 for 3RT1926
--
--
--
--
--
2500
2500
50
35
ˆ 5
ˆ 3.5
10 (to 10 ms)
ˆ – 15 %
ˆ – 1%
100 x 10
-25 ... +60
-40 ... +85
IP 40 cover
IP 20 terminals
2 x (0.5 ... 1.5),
2 x (0.75 ... 4)
2 x (0.5 ... 2.5)
2 x (18 ... 14)
M3
0.8 ... 1.2
Any
15/11
10 ... 55 / 0.35
IEC 61000-6-2/IEC 61000-6-4
Integrated into timing relay
6
s
,
3RT19 16-2E
3RT19 16-2F
3RT19 16-2G
3RT19 16-2L
3RT19 26-2E
3RT19 26-2F
3RT19 26-2G
0.85...1.1 x U
0.95 ... 1.05 times rated frequency
2 (1 W for 3RT1916-2L)
4
--
3
1
0.2
0.1
4
2500
5000
150
200 (OFF-delay,
without auxiliary voltage)
3RT1916-2L: 35 (OFF-delay,
with auxiliary voltage)
--
--
--
10 x 10
Integrated into 3RT19 16
6
s
,

Related parts for 3UG4622-1AW30