3UG4622-1AW30 SIEMENS, 3UG4622-1AW30 Datasheet - Page 103

RELAY, MONITOR, 22.5MM

3UG4622-1AW30

Manufacturer Part Number
3UG4622-1AW30
Description
RELAY, MONITOR, 22.5MM
Manufacturer
SIEMENS
Series
3UG46r
Datasheet

Specifications of 3UG4622-1AW30

Contact Configuration
SPCO
Power Consumption
4VA
Supply Voltage Max
240VAC
Contact Current Max
3A
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
230V
External Depth
86mm
Coil Frequency Max
60Hz
Coil Operating Frequency Min
50Hz
Technical specifications
• During operation
• During storage
• Enclosures
• Terminals
1) Electrical equipment for furnaces.
2) For relay outputs, use a fuse link:
3) For instantaneous output.
4) When the cascading input is supplied from A1, the maximum response
5) The drivers are not supplied, internal supply bridging only.
Type
Standards
Category acc. to EN 954-1
Test certificates
Rated insulation voltage U
• For control circuit
• For outputs
Rated impulse withstand voltage U
• For control circuit
• For outputs
Operating range
• DC operation
Rated operational currents I
acc. to IEC 60947-5-1
• I
• I
Short-circuit protection
Electrical endurance
Operating frequency z
in operating cycles/h during normal duty
Response time
• Monitored start
• Autostart
release time
• For EMERGENCY-STOP
• For supply failure
Recovery time
• For EMERGENCY-STOP
• For supply failure
Bridging of supply failures
Minimum command duration
• EMERGENCY-STOP
• ON button
Simultaneity
Conductor cross-sections
Screw-type connection
• Finely stranded with end sleeve
• Solid
• Tightening torque
Spring-loaded terminals
• Solid
• Finely stranded with end sleeve
• Finely stranded without end sleeve
• AWG conductors, solid or stranded
Permissible ambient temperature
Degree of protection acc. to EN 60529
Touch protection acc. to DIN VDE 0106 Part 100
Shock resistance
• Sinewave
Permissible mounting position
e
e
VDE certificate for 3TK28 41 and 3TK28 42 is available.
LV HRC Type 3NA, DIAZED Type 5SB, NEOZED Type 5SE:
6 A (weld-free protection at I
time is applicable to an external EMERGENCY-STOP.
SELV/PELV power supply unit buffered.
/AC-15
/ DC-13
i
e
K
= 1 kA).
at 115 V
at 230 V
at 24 V
imp
V
V
V
V
A
A
A
1/h
ms
ms
ms
ms
ms
s
ms
ms
s
ms
mm
mm
Nm
mm
mm
mm
°C
°C
g/ms 8/10 and 15/5
2
2
2
2
2
3TK28 40
EN 60204-1 (VDE 0113 Part 1), EN ISO 12100, EN 954-1, IEC 61508, DIN VDE 0116
TÜV, UL, CSA
50
50
500
500
0.9 ... 1.15 × U
--
--
0.5
Short-circuit proof
Unlimited, because switched electronically
3000
125
250
30
25
20
0.02
25
20
0.02
Š
2 × (0.5 ... 1.5), 1 × (0.5 ... 2.5)
2 × (0.5 ... 2.5), 1 × (0.5 ... 4)
0.8 ... 1.2
(1 or 2 conductors can be connected)
2 × (0.25 ... 1.5)
2 × (0.25 ... 1.0)
2 × (0.25 ... 1.5)
2 × AWG 24 ... 16
–25 ... +60
–40 ... +80
IP40
IP20
Finger-safe
Any
3
5)
s
3TK28 41
4
50
50
500
500
--
--
1.5
60
60
45
100
400
max. 7
25
25
0.2 ... 5
4)5)
4)
3TK28 Safety Relays
3TK28 42
4
50
50
500
500
--
--
1.5
60
60
45
(adjustable)
100
400
max. 7
25
30
0.2 ... 5
With electronic enabling circuits
3)
4)5)
4)
/0.05 ... 300 s
Siemens LV 1 T · 2006
3TK28 45
4
50
50/300
500
500/2000
2
--
1.5
Short-circuit proof
60
60
45
(adjustable)
100
400
max. 7
25
30
0.2 ... 5
3)
5)
/0.05 ... 300 s
1)
7/103
2)

Related parts for 3UG4622-1AW30