Specifications of LC1D09BL

Contact Configuration
DPCO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Length/height, External
77mm
Nom Operating Power
2.4W
External Width
45mm
Contact Voltage Ac Nom
600V
External Depth
95mm
Contact Form
N⁄O, N⁄C
Current, Rating
9 A
Current, Rating Max
9
Function
Contactor
Horse Power Rating
7.5
Number Of Poles
3
Primary Type
Contactor
Relay Type
Electro Mechanical
Voltage, Control
24 V
Voltage, Rating
600 VAC
Voltage, Supply
440 VAC
Operating Voltage
600VAC
Switching Power Ac1
1hp
Switching Power Ac3
7.5hp
Switching Current Ac1
20A
Switching Current Ac3
9A
Load Current Inductive
9A
Load Current Resistive
20A
No. Of Poles
3
Characteristics
Contact block type
Conforming to standards
Product certifications
Protective treatment
Degree of protection
Ambient air temperature
around the device
Maximum operating altitude
Cabling
Connection by spring terminals
Number of contacts
Rated operational voltage (Ue)
Rated insulation voltage (Ui)
Conventional thermal current (Ith)
Frequency of operational current
Minimum switching capacity
Short-circuit protection
Rated making capacity
Short-time rating
Insulation resistance
Non-overlap time
Overlap time
Time delay
(LAD-T, R and S contact blocks)
Accuracy only valid for setting range
indicated on the front face
Mechanical durability
Operational power of contacts
References:
pages 2/17 and 2/18
Environment
Instantaneous and time delay contact characteristics
2/38
Dimensions:
pages 2/44 and 2/45
Conforming to IEC 68
Conforming to VDE 0106
Storage
Operation
Permissible for operation at Uc
Without derating
Phillips N° 2 and Ø 6 mm
Flexible or solid cable with or without cable end
Flexible or solid cable without cable end
Up to
Conforming to EN 60947-5-1
Conforming to UL, CSA
For ambient temperature
U min.
I min.
Conforming to EN 60947-5-1 and VDE 0660. gG fuse A
Conforming to EN 60947-5-1, I rms
Permissible for:
Guaranteed between N/C and N/O contacts
Guaranteed between N/C and N/O on LAD-C22
Ambient air temperature for operation
Repeat accuracy
Drift up to 0.5 million operating cycles
Drift depending on ambient air temperature
In millions of operating cycles
TeSys contactors
Auxiliary contact blocks without
dust and damp protected contacts
for model d contactors
Schemes:
pages 2/48 and 2/49
1 s
500 ms
100 ms
60 °C
V
V
V
A
Hz
V
mA
A
A
A
A
M
ms
ms
°C
°C
°C
°C
m
mm
mm
2
2
1, 2 or 4
690
690
600
10
25…400
17
5
10
": 140; $: 250
100
120
140
> 10
1.5 (on energisation and on de-energisation)
1.5
30
See page 2/40
LAD-N or C LAD-T & S
IEC 947-5-1, NF C 63-140, VDE 0660, EN 60947-5-1
UL, CSA
“TH”
Protection against direct finger contact IP 2X
- 60…+ 80
- 5…+ 60
- 40…+ 70
3000
Min.: 1 x 1; max.: 2 x 2.5
Max.: 2 x 2.5
0.25 % per °C 0.25 % per °C –
2
- 40…+ 70
± 2 %
+ 15 %
5
LAD-R
2
- 40…+ 70
± 2 %
+ 15 %
5
Schneider Electric
LAD-8
2
30