LC1D09BL TELEMECANIQUE, LC1D09BL Datasheet - Page 6

Contactor

LC1D09BL

Manufacturer Part Number
LC1D09BL
Description
Contactor
Manufacturer
TELEMECANIQUE
Type
General Purposer
Datasheets

Specifications of LC1D09BL

Contact Configuration
DPCO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Length/height, External
77mm
Nom Operating Power
2.4W
External Width
45mm
Contact Voltage Ac Nom
600V
External Depth
95mm
Contact Form
N⁄O, N⁄C
Current, Rating
9 A
Current, Rating Max
9
Function
Contactor
Horse Power Rating
7.5
Number Of Poles
3
Primary Type
Contactor
Relay Type
Electro Mechanical
Voltage, Control
24 V
Voltage, Rating
600 VAC
Voltage, Supply
440 VAC
Operating Voltage
600VAC
Switching Power Ac1
1hp
Switching Power Ac3
7.5hp
Switching Current Ac1
20A
Switching Current Ac3
9A
Load Current Inductive
9A
Load Current Resistive
20A
No. Of Poles
3
Linked contacts conforming to
draft standard IEC 947-4-5
Mirror contact
Rated operational voltage (Ue)
Rated insulation voltage (Ui)
Conventional thermal current (Ith)
Operating current frequency
Minimum switching capacity
Short-circuit protection
Rated making capacity
Short-time rating
Insulation resistance
Non-overlap time
Contact operating power
conforming to EN 60947-5-1
1 million operating cycles
3 million operating cycles
10 million operating cycles
AC-15
Contactor integral auxiliary contact characteristics
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
= 10
1
8
7
6
5
4
3
2
1
0,1
–8
Characteristics
Selection:
pages 1/6 to 1/35
Schneider Electric
0,2
0,3
0,4
0,5
0,6
0,7
0,8
0,9
References:
pages 2/6 to 2/9
1
(continued)
a.c. supply categories AC-14 and AC-15
Electrical life (valid for up to 3600 operating cycles/hour)
on an inductive load such as the coil of an electromagnet:
making power (cos
(cos
V
VA
VA
VA
Each contactor has 2 N/O and N/C contacts mechanically linked on the same movable contact holder
The N/C contact on each contactor represents the state of the power contacts and can be connected to a
PREVENTA safety module
Up to
Conforming to IEC 947-1
Conforming to UL, CSA
For ambient temperature
U min.
I min.
Conforming to EN 60947-5-1
Conforming to EN 60947-5-1, I rms
Permissible for
Guaranteed between N/C and N/O contacts
0.4).
24
60
16
4
2
48
120
32
8
3
Current broken in A
4
115
280
80
20
0.7) = 10 times the power broken
5
6
230
560
160
40
7
TeSys contactors
Model d
60 °C
1 s
500 ms
100 ms
Dimensions:
pages 2/44 to 2/47
8
9
10
400
960
280
70
440
1050
300
80
DC-13
0,8
0,7
0,6
0,5
0,4
0,3
0,2
0,1
1
8
7
6
5
4
3
2
1
0,1
440 V
600
1440
420
100
0,2
250 V
V
V
V
A
Hz
V
mA
A
A
A
A
M
ms
d.c. supply category DC-13
on an inductive load such as the coil of an electromagnet,
without economy resistor, the time constant increasing
with the load.
V
W
W
W
Schemes:
pages 2/48 and 2/49
Electrical life (valid for up to 1200 operating cycles/hour)
0,3
125 V
24
96
48
14
0,4
690
690
600
10
25…400
17
5
gG fuse: 10 A
": 140, $: 250
100
120
140
> 10
1.5 on energisation and on de-energisation
0,5
0,6
48
76
38
12
48 V
0,7
0,8
0,9
1
125
76
38
12
24 V
250
76
32
2
440
44
3
Current broken in A
4
5
6
7
2/37
8
9
10
2

Related parts for LC1D09BL