Specifications of LC1D09BL

Contact Configuration
DPCO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Length/height, External
77mm
Nom Operating Power
2.4W
External Width
45mm
Contact Voltage Ac Nom
600V
External Depth
95mm
Contact Form
N⁄O, N⁄C
Current, Rating
9 A
Current, Rating Max
9
Function
Contactor
Horse Power Rating
7.5
Number Of Poles
3
Primary Type
Contactor
Relay Type
Electro Mechanical
Voltage, Control
24 V
Voltage, Rating
600 VAC
Voltage, Supply
440 VAC
Operating Voltage
600VAC
Switching Power Ac1
1hp
Switching Power Ac3
7.5hp
Switching Current Ac1
20A
Switching Current Ac3
9A
Load Current Inductive
9A
Load Current Resistive
20A
No. Of Poles
3
Conforming to standards
Product certifications
Protective treatment
Degree of protection
Ambient air temperature
around the device
Module type
Rated insulation voltage
Rated operational voltage
Indication of input state
Input signals
Built-in protection
Electrical durability at 220/240 V
Maximum immunity time
to micro-breaks
Power dissipated
Direct mounting without contactor
Mounting with cabling adaptor
LAD-4BB
Total operating time
at Uc (of the contactor)
Cabling
Environment
Other characteristics
Characteristics
References:
page 2/21
Schneider Electric
Dimensions:
pages 2/44 and 2/45
Conforming to IEC 68
Conforming to VDE 0106
Storage
Operation
Permissible for operation at Uc
Conforming to EN 60947-5-1
Conforming to EN 60947-5-1
By integral LED which illuminates when the contactor coil is energised
Control voltage (E1-E2)
Permissible variation
Current consumption at 20 °C
State “0” guaranteed for
State “1” guaranteed for
Against reverse polarity
Of the input
In millions of operating cycles
At 20 °C
With coil:
With coil:
Operating times depend on the type of contactor electromagnet and its control mode.
The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles.
The opening time “O” is measured from the moment the coil supply is switched off to the moment the main poles
separate.
With LA4-DF, DL
Phillips N° 2 and Ø 6 mm
Flexible or solid cable
with or without cable end
" 24…250 V
" 100…250 V
" 380…415 V
" 24…250 V
" 380…415 V
TeSys contactors
Interface modules
for model d contactors
Schemes:
pages 2/48 and 2/49
U
I
U
N/O ms
N/C ms
°C
°C
°C
V
V
V
V
mA
V
mA
V
ms
W
mm
mm
2
2
IEC 255-5
UL, CSA
“TH”
Protection against direct finger contact IP 2X
- 40…+ 80
- 25…+ 55
- 25…+ 70
LA4-
DFBQ
With
relay
5
415
$ 24
17…30
25
< 2.4
< 2
17
By diode
By diode
3
4
0.6
LC1-D40…D150 –
LC1-D09…D38,
DT20…DT60
LC1-D09…D38,
DT20…DT60
20…30
16…24
Min.: 1 x 1
Min.: 2 x 2.5
LA4-
DFB
With
relay
250
250
$ 24
17…30 33…60 17…30 33…60 5…30
25
< 2.4
< 2
17
10
4
0.6
LC1-D40…D150
LC1-D09…D38,
DT20…DT60
LA4-
DFE
With
relay
$ 48
15
< 4.8
< 1.3
33
10
4
0.6
LC1-D40…D65
28…34
20…24
LA4-
DLB
With relay
+ override
$ 24
25
< 2.4
< 2
17
3
4
0.6
LA4-
DLE
$ 48
15
< 4.8
< 1.3
33
3
4
0.6
LC1-D80 and D95
28…43
18…32
LA4-
DWB
Solid
state
$ 24
8.5 for 5 V
15 for 24 V
< 2.4
< 2
5
20
1
0.4
LC1-D40…D115
LC1-D09…D38,
DT20…DT60
2/43