LC1D09BL TELEMECANIQUE, LC1D09BL Datasheet - Page 3

Contactor

LC1D09BL

Manufacturer Part Number
LC1D09BL
Description
Contactor
Manufacturer
TELEMECANIQUE
Type
General Purposer
Datasheets

Specifications of LC1D09BL

Contact Configuration
DPCO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Length/height, External
77mm
Nom Operating Power
2.4W
External Width
45mm
Contact Voltage Ac Nom
600V
External Depth
95mm
Contact Form
N⁄O, N⁄C
Current, Rating
9 A
Current, Rating Max
9
Function
Contactor
Horse Power Rating
7.5
Number Of Poles
3
Primary Type
Contactor
Relay Type
Electro Mechanical
Voltage, Control
24 V
Voltage, Rating
600 VAC
Voltage, Supply
440 VAC
Operating Voltage
600VAC
Switching Power Ac1
1hp
Switching Power Ac3
7.5hp
Switching Current Ac1
20A
Switching Current Ac3
9A
Load Current Inductive
9A
Load Current Resistive
20A
No. Of Poles
3
Characteristics
Type of contactor
Rated operational current (Ie)
(Ue
Rated operational voltage (Ue)
Frequency limits
Conventional thermal current (Ith)
Rated making capacity (440 V)
Rated breaking capacity (440 V)
Permissible short-time rating
No current flowing for preceding
15 minutes at
Protection by fuse
against short-circuits (U
Average impedance per pole
Power dissipation per pole
for the above operating currents
Rated control circuit voltage (Uc)
Control voltage limits
Average consumption
at 20 °C and at Uc
Heat dissipation
Operating time (3)
Mechanical life
in millions of operating cycles
Maximum operating rate
at ambient temperature
(1) Protection ensured for the connection cross-sections shown on page 2/33 and for connection via cable.
(2) In the least favourable direction, without change of contact state (coil supplied at Ue).
(3) The closing time “C” is measured from the moment the coil supply is switched on to initial contact of the main poles. The opening time “O” is measured from
the moment the coil supply is switched off to the moment the main poles separate.
Selection:
pages 1/6 to 1/35
Pole characteristics
a.c. control circuit characteristics
2/34
440 V)
50 or 60 Hz coils
50/60 Hz coils
40 °C
60 °C
690 V)
" 60 Hz Inrush
50/60 Hz
" 50 Hz Inrush
References:
pages 2/6 to 2/9
In AC-3,
In AC-1,
Up to
Of the operating current
Conforming to IEC 947
Conforming to IEC 947
For 1 s
For 10 s
For 1 min
For 10 min
Without thermal overload relay,
fuse gG
With thermal overload relay
At Ith and 50 Hz
AC-3
AC-1
50/60 Hz
Operational
Drop-out
Operational
Drop-out
Sealed
Sealed
Closing “C”
Opening “O”
50 or 60 Hz coil
50/60 Hz coil on 50 Hz
In operating cycles per hour
60 °C
60 °C
60 °C
50 Hz coil
Cos
50/60 Hz coil
50 Hz coil
Cos
50/60 Hz coil
60 Hz coil
Cos
50/60 Hz coil
60 Hz coil
Cos
50/60 Hz coil
TeSys contactors
Model d
Dimensions:
pages 2/44 to 2/47
type 1
type 2
LC1-
A
A
V
Hz
A
A
A
A
A
A
A
A
m
W
W
V
VA
VA
VA
VA
VA
VA
VA
VA
W
ms
ms
D09
9
25
690
25…400
25
250
250
210
105
61
30
25
20
See pages 2/52 and 2/53, for aM or gG fuse ratings
corresponding to the associated thermal overload relay
2.5
0.20
1.56
12…690
0.8…1.1 Uc on 50 Hz and
0.85…1.1 Uc on 60 Hz at 60 °C
0.3…0.6 Uc at 60 °C
0.75
70
0.3
7
0.75
70
0.3
7.5
2…3
12…22
4…19
15
3600
Schemes:
pages 2/48 and 2/49
DT20
20
20
D12
12
25
690
25…400
25
250
250
210
105
61
30
40
25
2.5
0.36
1.56
DT25
25
D18
18
32
690
25…400
32
300
300
240
145
84
40
50
35
2.5
0.8
2.5
DT32
32
Schneider Electric
D25
25
40
690
25…400
40
450
450
380
240
120
50
63
40
2
1.25
3.2
DT40