IDTTS3000B3ANRG8 IDT, Integrated Device Technology Inc, IDTTS3000B3ANRG8 Datasheet

no-image

IDTTS3000B3ANRG8

Manufacturer Part Number
IDTTS3000B3ANRG8
Description
IC TEMP SENS LOCAL DFN-8
Manufacturer
IDT, Integrated Device Technology Inc
Datasheet

Specifications of IDTTS3000B3ANRG8

Function
Temp Monitoring System (Sensor)
Topology
ADC (Sigma Delta), Control Logic, Register Bank
Sensor Type
Internal
Sensing Temperature
-20°C ~ 125°C
Output Type
2-Wire Serial, I²C™/SMBUS™
Output Alarm
Yes
Output Fan
No
Voltage - Supply
3 V ~ 3.6 V
Operating Temperature
-20°C ~ 125°C
Mounting Type
Surface Mount
Package / Case
8-WFDFN Exposed Pad
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
800-2035-2
Description
The TS3000B3A digital temperature sensor with accuracy up to ±0.5°C
was designed to target applications demanding highest level of
temperature readout. The sensor is fully compliant with JEDEC JC42.4
Component Specification.
The digital temperature sensor comes with several user-programmable
registers to provide maximum flexibility for temperature-sensing
applications. The registers allow specifying critical, upper, and lower
temperature limits as well as hysteresis settings. Both the limits and
hysteresis values are used for communicating temperature events from
the chip to the system. This communication is done using Event pin,
which has an open-drain configuration. The user has the option of setting
the Event pin polarity as either an active-low or active-high comparator
output for thermostat operation, or as a temperature event interrupt
output for microprocessor-based systems.
The sensor uses an industry standard 2-wire, I
interface, and allows up to eight devices to be controlled on the bus.
Typical Server or Laptop Applications
© 2010 Integrated Device Technology, Inc.
Master Device
management
I2C/SMBus
Controller
Controller
Any other
Thermal
Board
Or
Or
MCH
EVENT
EVENT
SMBus
SMBus
IDT and the IDT logo are registered trademarks of Integrated Device Technology, Inc.
Temperature
Temperature
®
Sensor
Sensor
Local
Local
Local Temperature Sensor
*Notice: The information in this document is subject to change without notice
2
C/SMBus serial
Sensors is Application
Total Number of
Dependent
1 of 21
Features
Temperature Sensor Features
Typical Applications
– Active mode
– Shutdown mode
- Meets strict SMBus spec of 25ms (min) 35ms (max)
Temperature Sensor
Single Supply: 3V to 3.6V
Accurate timeout support
Timeout supported in all Modes
Schmitt trigger and noise filtering on bus inputs
2-wire Serial Interface: 10-400 kHz I
Available Packages: DFN-8, TDFN-8
Temperature Converted to Digital Data
Sampling Rate of 100ms (max)
Selectable 0, 1.5°C, 3°C, 6°C Hysteresis
Programmable Resolution from 0.0625°C to 0.5°C
Accuracy:
DIMM Modules (DDR2, DDR3), SSD Boards
Servers, Laptops, Ultra-portables, PC Boards
High end audio / video equipment
Portable devices
Hard Disk Drives and Other PC Peripherals
±0.5°C/±1°C (typ./max.) from -20°C to +125°C
Advance Information*
2
IDT Confidential
C™ /SMBus™
TS3000B3A
Data Sheet
May 12, 2010
DSC 7312/6

Related parts for IDTTS3000B3ANRG8

IDTTS3000B3ANRG8 Summary of contents

Page 1

Description The TS3000B3A digital temperature sensor with accuracy up to ±0.5°C was designed to target applications demanding highest level of temperature readout. The sensor is fully compliant with JEDEC JC42.4 Component Specification. The digital temperature sensor comes with several ...

Page 2

Block Diagram: Temperature Sensor May 12, 2010 ...

Page 3

Maximum Ratings Stressing the device above the rating listed in the Absolute Maximum Ratings table may cause permanent damage to the device. These are stress ratings only and operation of the device at these or any other conditions above those ...

Page 4

AC Measurement Conditions Symbol Parameter C Load capacitance L Input rise and fall times Input levels Input and output timing reference levels AC Measurement I/O Waveform Input Parameters for the TS3000B3A 1,2 Symbol Parameter C Input capacitance (SDA ...

Page 5

DC Characteristics Parameter Input Leakage Current (SCL, SDA) Output Leakage Current Supply Current, temp sensor active Standby Supply Current Input Low Voltage (SCL, SDA) Input High Voltage (SCL, SDA) SA0 High Voltage Output Low Voltage Input hysteresis Symbol Conditions I ...

Page 6

AC Characteristics Parameter Clock Frequency Clock Pulse Width High Time Clock Pulse Width Low Time Detect clock low timeout, Capabilities Register bit 6 =1 SDA Rise Time SDA Fall Time Data In Setup Time Data In Hold Time Data Out ...

Page 7

Temperature-to-Digital Conversion Performance Parameter Temperature Sensor Accuracy 1. V < V < V DDMIN DD DDMAX Temperature Conversion Time Resolution ADC Setting 0.5°C 0.25°C (POR default) 0.125°C 0.0625°C Min Typ Max Unit ±0.5 ±1.0 °C t (typ) t CONV CONV ...

Page 8

Pin Assignment SA0 SA0 SA0 SA1 SA1 SA1 SA2 SA2 SA2 VSS VSS VSS Pin Description ...

Page 9

Maximum R Value vs. Bus Capacitance (C L Select Address (SA0, SA1, SA2) These input signals are used to set the value that looked for on the three least significant bits (b3, b2, b1) of the 7-bit ...

Page 10

EVENT Pin Mode Functionality Event Thresholds All event thresholds use hysteresis as programmed in register 0x01 bits 10:9 to set when they deassert (stop driving). Alarm Window Trip The device provides a comparison window with an upper temperature trip point ...

Page 11

Comparator Mode Reads/writes on the device registers will not affect the EVENT# output in comparator mode. The EVENT# signal will remain asserted until the temperature drops outside the range, or the range is re-programmed such that the current temperature is ...

Page 12

SMBus/I C write to the pointer register 2 SMBus/I C write to the pointer register followed by a write data word 2 SMBus/I C word read from register with a preset pointer May 12, 2010 ...

Page 13

SMBus/I C write to pointer register followed by a repeat start and an immediate data word read 2 SMBus/I C Slave Sub-Address Decoding The physical address for TS is different than that used by current SPD devices. The physical ...

Page 14

The meaning of the A0/A1/A2 pin states is as follows:; 0= Pull-down to Thermal Sensor Vss, 1=Pull-up to Thermal Sensor VDD SMBus/I2 AC Timing Consideration In order for this device to be both SMBus and I considerations to ensure interoperability. ...

Page 15

Temperature Register Addresses ADDR R/W Name N/A W Address Pointer 00 R Capabilities 01 R/W Configuration 02 R/W High Limit 03 R/W Low Limit 04 R/W TCRIT Limit 05 R Ambient Temperature 06 R Manufacturer Device/Revision 08 ...

Page 16

TRES Bit Decode TRES[1: 0.5°C (9-bit 0.25°C (10-bit) (default 0.125°C (11-bit 0.0625°C (12-bit) Note: Refer to section Resolution Register on page 19. Bit 2 - RANGE; Indicates the supported temperature ...

Page 17

Hysteresis T = Value stored in Alarm Temperature Upper Boundary Trip Register U T =Value stored in Alarm Temperature Lower Boundary Trip Register L Hyst= Absolute value of selected hysteresis Temperature Register Value Definitions Temperatures in the High Limit Register, ...

Page 18

The TRES field of the Capabilities Register optionally defines higher resolution devices. For compatibility and simplicity, this additional resolution affects only the Temperature Data Register but none of the Limit Registers. When higher resolution devices generate status or EVENT changes, ...

Page 19

Temperature Data Register Temperature Data Register ADDR R/W B15/B7 B14/B6 TCRIT HIGH Resolution defined based on value of TRES field of the Capabilities Register. Unused/unsupported bits will read as 0. The Temperature Data Register holds ...

Page 20

Resolution Register ADDR R/W B15/B7 B14/B6 08h R Legend: Resolution bits 4-3 TRES[4: LSB = 0.5°C (register value = 0007 LSB = 0.25°C (register value = 000F LSB = 0.125°C ...

Page 21

Ordering Information XXXX Voltage Device Type Temp Range Example: TS3000B3A NRG8 CORPORATE HEADQUARTERS 6024 Silver Creek Valley Road San Jose, CA 95138 ® XXX Shipping Rev. Package Carrier Tape and Reel 8 NCG Green TDFN ...