ML610Q412P-NNNTB03A7 Rohm Semiconductor, ML610Q412P-NNNTB03A7 Datasheet - Page 148

no-image

ML610Q412P-NNNTB03A7

Manufacturer Part Number
ML610Q412P-NNNTB03A7
Description
MCU 8BIT 16K FLASH 120-TQFP
Manufacturer
Rohm Semiconductor

Specifications of ML610Q412P-NNNTB03A7

Core Processor
nX-U8/100
Core Size
8-Bit
Speed
625kHz
Connectivity
I²C, SSP, UART/USART
Peripherals
LCD, POR, PWM, WDT
Number Of I /o
14
Program Memory Size
16KB (8K x 16)
Program Memory Type
FLASH
Ram Size
1K x 8
Voltage - Supply (vcc/vdd)
1.1 V ~ 3.6 V
Data Converters
A/D 2x12b, 2x24b
Oscillator Type
Internal
Operating Temperature
-40°C ~ 85°C
Package / Case
*
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Eeprom Size
-

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
ML610Q412P-NNNTB03A7
Manufacturer:
ROHM
Quantity:
750
Part Number:
ML610Q412P-NNNTB03A7
Manufacturer:
Rohm Semiconductor
Quantity:
10 000
10.3.2
The frequency measurement mode in 16-bit timer 2&3, is used to count the frequency of 500kHz RC oscillation clock
which typically has temperature variation and production tolerance.
Using the frequency measurement mode can make better accuracy for uart baud-rate clock or timer function.
(1) Reading the count data, caluculating and setting it to uart communication baud-rate registers, can make more
accurate baud-rate clock.
(2) Reading the count data, caluculating and setting it to a timer data register, can make more accurate timing in normal
timer mode.
Note:
This function is not available on ML610Q415 because it does not have low-speed crystal oscillation clock.
Figure 10-3 shows the operation timing in frequency measurement mode.
(1) High-speed clock (HSCLK, HTBCLK) has to be in oscillating state by conrolling with FCONn registers.
(2) Reset both T2RUN bit (bit0 of TM2CON1 register) and T3RUN bit (bit0 of TM3CON1 register) to “0” to
stop the timer. And then, check both T2STAT bit (bit7 of TM2CON1 register) and T3STAT bit (bit7 of
TM3CON1 register) are “0” for making certain the timer stops.
(3) Set T23MFM bit (bit3 of TM2CON0 register) to “1” (Frequency measurement mode), set T23M16 bit
And also set HTBDR register (High-speed Time Base counter Devide Register) per necessory.
T23MFM
(bit2of TM2CON0 register) to “1” (16bit mode) and set T2CS1-0 bits(bit1/0 of TM2CON0 register) to
“01”(HTBCLK mode).
T2STAT
T23M16
TM3INT
16-bit timer frequency measurement mode operation
T2RUN
{TM3C,TM2C}
FFFF
437C
64Hz
0000
N1
(H)
Figure 10-3 Operation Timing in frequency measurement mode
(3)
(5)
(6)
(7)
10 – 21
ML610Q411/ML610Q412/ML610Q415 User’s Manual
437/32768S
(8)
Chapter 10 Timers