H7CX-A11D1-N DC12-24/AC24 Omron, H7CX-A11D1-N DC12-24/AC24 Datasheet - Page 34

Tachometers 11-pin SPDT 6 Digits 12-24VDC/VAC24

H7CX-A11D1-N DC12-24/AC24

Manufacturer Part Number
H7CX-A11D1-N DC12-24/AC24
Description
Tachometers 11-pin SPDT 6 Digits 12-24VDC/VAC24
Manufacturer
Omron
Type
1 Stage and Total Preset Counterr

Specifications of H7CX-A11D1-N DC12-24/AC24

Frequency Response
50 Hz
Product
Panel Mount Tachometer
Voltage
12 VDC to 24 VDC, 24 VAC
Display Type
6 Digit
Accuracy
+/- 0.1 %
No. Of Digits / Alpha
6
Digit Height
10mm
Power Consumption
4.7W
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Meter Function
Counter
Signal Input Type
PNP/NPN
Character Size
9mm
Supply Voltage Min
12VDC
Rohs Compliant
Yes
Connector Type
11-Pin Socket
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
34
H7CX-A@-N
Output Mode Setting and Operation
Tachometer Operation
1 input
Error
Absolute ratio
Error ratio
2 inputs
Input mode
setting
Output mode
Area (AREA)
Upper limit
Lower limit
Upper limit
Lower limit
Upper and
lower limit
(LO-LO)
setting
(HI-LO)
(HI-HI)
(LO)
(HI)
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Output 1
Comparison value 1
Output 1
Comparison value 1
Measurement value
Measurement value
Measurement value
Measurement value
CP1 display value
CP1 display value
ON condition for output 1: CP1 present value (display value)
ON condition for output 2: CP2 present value (display value)
ON condition for output 1: CP1 present value (display value)
ON condition for output 2: CP2 present value (display value)
(Upper-limit)
(Lower-limit)
(Upper-limit)
(Lower-limit)
(Upper-limit)
(Lower-limit)
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT1
OUT2
OUT1
OUT1
ON condition for OUT1: Measurement value
ON condition for OUT2: Measurement value
ON condition for OUT1: Measurement value
ON condition for OUT2: Measurement value
ON condition for OUT1: Measurement value
ON condition for OUT2: Measurement value
ON condition
for OUT1
ON condition
for OUT2
Condition
Operation
Output 2
Comparison value 2
Output 2
Comparison value 2
CP2 display value
CP2 display value
Comparison value 1
Measurement value
Comparison value 2
Measurement value <
Comparison value 1 or
Measurement value >
Comparison value 2
Comparison value 1
Comparison value 2
OUT2
OUT2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 1
Comparison value 2
Comparison value 2
Measurement value
Comparison value 1
Measurement value <
Comparison value 2 or
Measurement value >
Comparison value 1
Measurement value 1 >
Comparison value 2