H7CX-A11D1-N DC12-24/AC24 Omron, H7CX-A11D1-N DC12-24/AC24 Datasheet - Page 23

Tachometers 11-pin SPDT 6 Digits 12-24VDC/VAC24

H7CX-A11D1-N DC12-24/AC24

Manufacturer Part Number
H7CX-A11D1-N DC12-24/AC24
Description
Tachometers 11-pin SPDT 6 Digits 12-24VDC/VAC24
Manufacturer
Omron
Type
1 Stage and Total Preset Counterr

Specifications of H7CX-A11D1-N DC12-24/AC24

Frequency Response
50 Hz
Product
Panel Mount Tachometer
Voltage
12 VDC to 24 VDC, 24 VAC
Display Type
6 Digit
Accuracy
+/- 0.1 %
No. Of Digits / Alpha
6
Digit Height
10mm
Power Consumption
4.7W
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Meter Function
Counter
Signal Input Type
PNP/NPN
Character Size
9mm
Supply Voltage Min
12VDC
Rohs Compliant
Yes
Connector Type
11-Pin Socket
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Note: 1. The full scale (FS) for H7CX 4-digit models is 9999.
Output
mode
setting
2. When the present value reaches 999999, it returns to 0.
3. Counting cannot be performed during reset/reset 1 input.
4. If reset/reset 1 is input while one-shot output is ON, one-shot output turns OFF.
5. If there is power failure while output is ON, output will turn ON again when the power supply has recovered.
6. Do not use the counter function in applications where the count may be completed (again) while one-shot output is ON.
7. The setting range is 0 to 999,999 (0 to 9,999 for 4-digit models).
For one-shot output, output will turn ON again for the duration of the output time setting once the power supply has recovered.
Q
A
P
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
999999
reset 1
Reset/
OUT1
OUT2
999999
reset 1
Reset/
OUT1
OUT2
999999
reset 1
Reset/
OUT1
OUT2
0
0
0
UP
Input mode
DOWN
Self-holding
output
UP/DOWN A, B, C
One-shot output from OUT1
Self-holding
output
output from OUT2
One-shot
H7CX-A@-N
The present value
display does not
change during the
one-shot output time
period, but the actual
count returns to the
reset start status.
The output will return
to one-shot mode.
The outputs repeat
one-shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
continues to increase/
decrease for the one-
shot output time, but
returns to the reset
start status after the
one-shot output time
has elapsed.
The outputs repeat
one-shot operation.
OUT1 self-holding
output turns OFF after
the OUT2 one-shot
output time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display and OUT1
self-holding output is
held until reset/reset 1
is input.
OUT1 and OUT2 are
independent.
(The one-shot output time ca
set in the range 0.01 to 99.9
count completion
Operation after
Counter
23