H7CX-A11D1-N DC12-24/AC24 Omron, H7CX-A11D1-N DC12-24/AC24 Datasheet - Page 22

Tachometers 11-pin SPDT 6 Digits 12-24VDC/VAC24

H7CX-A11D1-N DC12-24/AC24

Manufacturer Part Number
H7CX-A11D1-N DC12-24/AC24
Description
Tachometers 11-pin SPDT 6 Digits 12-24VDC/VAC24
Manufacturer
Omron
Type
1 Stage and Total Preset Counterr

Specifications of H7CX-A11D1-N DC12-24/AC24

Frequency Response
50 Hz
Product
Panel Mount Tachometer
Voltage
12 VDC to 24 VDC, 24 VAC
Display Type
6 Digit
Accuracy
+/- 0.1 %
No. Of Digits / Alpha
6
Digit Height
10mm
Power Consumption
4.7W
Counting Speed
5kHz
Operating Temperature Range
-10°C To +55°C
Meter Function
Counter
Signal Input Type
PNP/NPN
Character Size
9mm
Supply Voltage Min
12VDC
Rohs Compliant
Yes
Connector Type
11-Pin Socket
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
22
H7CX-A@-N
Counter
Input/Output Mode Settings
I/O Functions for Counter Operation
If a 1-stage model or 2-stage model is incorrectly used as twin counter, the operation for
output 2 will be performed. When using a 2-stage model as a 1-stage preset counter,
total and preset counter, or dual counter, OUT1 and OUT2 turn ON and OFF
simultaneously.
Output
mode
setting
K-1
N
C
R
F
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
Set value 2
Set value 1
999999
999999
999999
999999
reset 1
reset 1
999999
reset 1
reset 1
reset 1
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
Reset/
OUT1
OUT2
0
0
0
0
0
UP
Input mode
DOWN
Self-holding
output
UP/DOWN A, B, C
One-shot output from OUT1
Self-holding
output
output from OUT2
One-shot
(The one-shot output time can be
set in the range 0.01 to 99.99s.)
The outputs and present
value display are held
until reset/reset 1 is
input.
The present value
display continues to
increase/decrease.
The outputs are held until
reset/reset 1 is input.
As soon as the count
reaches SV, the present
value display returns to
the reset start status.
The present value display
does not show the
present value upon count-
up.
The outputs repeat one-
shot operation.
OUT1 self-holding output
turns OFF after the OUT2
one-shot output time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display returns to the
reset start status after
the one-shot output time.
The outputs repeat one-
shot operation.
OUT1 self-holding output
turns OFF after the
OUT2 one-shot output
time.
The OUT1 one-shot
output time is
independent of OUT2.
The present value
display continues to
increase/decrease.
OUT1 self-holding output
turns OFF after the
OUT2 one-shot output
time.
The OUT1 one-shot
output time is
independent of OUT2.
Operation after count